Bloomfield WV-2HSGRWT, WV-2HFGRWT operation manual Ventilator Section, Description Comment

Page 5

508 p/n 304456 OpManual WV-2H Series Ventless Combo Cook Center

VENTILATOR SECTION

ITEM

DESCRIPTION

COMMENT

1.

NAMEPLATE

Gives manufacturer, make and model description. Also lists voltage

 

 

and amperage data.

5.

APPLIANCE LIGHT

ON when hood power switch is ON. Illuminates cooktop.

a6.

FIRE SUPPRESSION

Container for Ansulex™ Low-pH liquid fire suppression liquid.

 

AGENT TANK (1.5 gal.)

 

8.

ADJUSTABLE (FRONT) LEG

Allows the unit to be leveled.

9.

RIGID (REAR) CASTER

Allows the unit to be easily positioned by lifting the front of the unit

 

 

slightly.

a10.

MANUAL PULL STATION

Provides a means of manual activation of the fire suppression system.

 

 

PULL ONLY IN CASE OF FIRE!

a11.

FUSIBLE LINKS

Designed to break at rated temperature. Breaking (i.e. fire on the

 

 

cooktop) activates fire suppression system. Should be replaced at

 

 

least once per year.

12.

LOWER REAR ACCESS

Allows access to Ansul® fire suppression agent tank (a6) and controls

 

PANEL

also access to main power contactor (41).

a15.

DISCHARGE NOZZLE

Fire suppression media discharges here (2 places).

16.

GREASE BAFFLE

Extracts and drains most grease and moisture from the air flow.

18.

PRE-FILTER ASSEMBLY

Comprises the PRE-FILTER FRAME and a replaceable

 

 

PRE-FILTER. Stops larger particles of grease from reaching the

 

 

FILTER PACK for reduced maintenance costs.

19.

HI-EFFICIENCY/CHARCOAL

Stops most grease and smoke particles. Also assists in some cooking

 

FILTER PACK

odor removal.

22.

GREASE DRIP TRAY

Collects grease/moisture dripping from grease baffle(16).

28.

VENTILATOR EXHAUST

Exit point for ventilator airflow - on top left rear of unit.

 

DUCT

DO NOT BLOCK

a31.

STATUS INDICATOR

Displays status of fire suppression system (COCKED - FIRED) If

 

 

FIRED, a buzzer will sound continuously.

38.

POWER CORD

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

41.

POWER CONTACTOR

Energizes cooking appliances only while ventilator section is sensed

 

 

as operational.

42.

BUILDING FIRE ALARM

Reports fire alarm condition to building fire management system.

 

RELAY

 

43.

GROUND LUG

Ground wire of power cord connects here.

44.

INTERLOCK TERMINAL

Provides connection for shut-down control by building fire management

 

 

system.

53.

FILTER INTERLOCK

Proper installation of grease baffle and filter pack close these switches

 

SWITCHES

in ventilator sensor circuit.

56.

VENTILATOR FAN

Provides air movement for ventilation.

57.

HOOD SIDE SHIELD

Required on left and right sides of hood. Factory installed.

58.

SIDE SPACERS

Required to maintain 6" spacing from combustibles. Field installed.

3

Image 5
Contents Important do not Discard this Manual 508Page Back Side Bottom TOP IntroductionVentilator Section Operating Features & Controls Description Comment Ventilator SectionVentilator Section Controls & Indicator Lights Optional Drawer Warmer Section Ventilator Section ControlsGriddle Section Hotplate Section Electric Shock Hazard Fire HazardHOT Surface Risk DamageVentilator Indicators Setup InstallationUnpacking & Inspection Risk InjuryPage Authority Having Jurisdiction Fire Suppression System InstallationInstallation Roll Warmer Drawer Installation Grease Drip Tray InstallationDo not Operate Unless the Grease Drip Tray is Installed Burn HazardPRE-FILTER Element OperationVentilator Operation Griddle Operation Preparing the Griddle Surface Using the GriddleSeasoning Standard Griddles Chrome Plated GriddlesHeating Options Operating Chart for Drawer WarmersItem Description RWT- Control Module SET Setpoint TemperatureChange Display Mode ºF or ºC Ventilator Section Cleaning Instructions Cleaning InstructionsCleaning PreparationHot Surface Hotplate SectionFrequency Daily Precautions Griddle Cleaning InstructionsElectrical Shock Hazard Heat Smoke HazardPrecautions Drawer Warmer Cleaning InstructionsFrequency ToolsHOT Surface Adjustments and LubricationShock Hazard Symptom Possible Cause Recommended Remedy Fire Hazard Maintenance SchedulesWells BLOOMFIELD, LLC Wells BLOOMFIELD, LLC Ansul Health Hazards Wells Bloomfield, LLC Genuin e Parts

WV-2HFGRW, WV-2HFG, WV-2HSGRW, WV-2HFGRWT, WV-2HSGRWT specifications

Bloomfield WV-2HSG, WV-2HSGRWT, WV-2HSGRW, WV-2HFGRW, and WV-2HFGRWT are innovative technologies designed to enhance various sectors, particularly in the fields of heating, ventilation, and air conditioning (HVAC). These models are recognized for their efficiency, versatility, and advanced features, making them popular choices among homeowners and professionals alike.

One of the standout features of the Bloomfield WV-2HSG series is its energy efficiency. These units are designed to consume less energy while providing maximum output, helping users save on utility bills without sacrificing comfort. The incorporation of environmentally friendly refrigerants also aligns with modern sustainability goals, reducing the overall carbon footprint of these systems.

The WV-2HSG model is particularly noted for its superior heating capabilities, which are ideal for colder climates. Its cutting-edge heat exchange technology ensures rapid heating and consistent temperature regulation throughout the space. This model is equipped with a user-friendly control interface, allowing for easy adjustments and programming of heating cycles to suit different preferences and schedules.

In contrast, the WV-2HSGRWT and WV-2HSGRW models emphasize adaptability in various humidity and air quality conditions. These systems feature advanced humidity sensors that monitor indoor conditions and automatically adjust operations to maintain a comfortable atmosphere. This is especially beneficial for areas prone to high humidity levels, as it prevents mold growth and promotes healthier living environments.

The WV-2HFGRW and WV-2HFGRWT variants stand out with their innovative filtration systems, which capture airborne particles, allergens, and contaminants. These models integrate HEPA filters coupled with activated carbon layers, ensuring clean and pure air circulation within the home. This characteristic is particularly appealing to individuals with allergies or respiratory issues, as it enhances overall indoor air quality.

All models within this range come equipped with smart technology integrations, enabling remote operation through smartphones and smart home systems. This not only adds convenience for users but also allows for monitoring and managing energy consumption effectively. Together, these features position the Bloomfield WV-2HSG series as exemplary products in the HVAC industry, merging efficiency, functionality, and cutting-edge technology to meet the needs of modern consumers.