SERVICING INSTRUCTIONS (continued)
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
A. (OLD-STYLE)
Remove hex nut holding inlet fitting into back of brewer. Remove two screws holding access door in place. Remove access door. Remove front panel.
On faucet models, remove flare connection from “tee” inlet fitting.
Push solenoid forward slightly and lift to release it from bracket.
Disconnect wiring and remove rubber tubing from solenoid.
Remove fittings from old solenoid and transfer to new solenoid. If necessary, replace flow control at this time.
B. (NEW-STYLE)
Unscrew water inlet fitting from solenoid.
Remove two screws holding access door in place. Remove two screws holding solenoid to door.
Remove brew water tube from solenoid. On faucet models, remove faucet water tube from bypass side of solenoid by pressing the white ring portion of the tube fitting tightly against the metal portion while pulling the tube off of the solenoid.
Disconnect wiring from solenoid.
Transfer solenoid bracket to new solenoid.
| Reassemble in reverse order. |
| CLEAN SOLENOID SCREEN |
| Symptom: Automatic brewer will not flow water. |
| Unplug power cord or turn circuit breaker OFF. Turn OFF and |
| disconnect water supply from brewer inlet fitting. |
| Unscrew water inlet fitting from solenoid. |
| Using |
| Clean screen under faucet. A stiff bristle brush may be used if |
| necessary. |
Fig. 11 Clean Strainer Screen | Reinsert screen in solenoid. Be careful to maintain correct |
| orientation. (The OPEN END of the screen goes in FIRST.) |
| Reassemble in reverse order. |
14