Bloomfield 8572, 8540, 8541, 8542, 8573 Leveling the Unit, PLUMBER’S Installation Instructions

Page 6

INSTALLATION INSTRUCTIONS

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT:

To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started:

CAUTION: Equipment

Electrical Damage

DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed.

CAUTION: Unstable

Equipment Hazard

REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR COMPONENT NAMES/NUMBERS

Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit.

Verify that the Spray Head Gasket (#33) and Spray Disk (#34) are properly installed.

LEVELING THE UNIT

Verify that an adjustable leg is installed at each corner of the brewer.

Set Brewer in its operating location. Level the Brewer. A spirit level should be placed on the top of the unit, at the edge, as a guide when making level adjustments.

Level the unit from left to right and front to back by turning the adjustable feet. Be sure all four feet touch the counter to prevent tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS

It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position. Provided adjustable, non-skid legs must be installed at each corner of the unit. Failure to do so will result in movement of the brewer which can cause personal Injury and/ or damage to brewer.

NOTE: Water supply inlet line must meet certain minimum criteria to insure successful operation of the brewer. Bloomfield recommends 1/4" copper tubing for installation of less than 25 feet and 3/8" for more than 25 feet from a 1/2" water supply line.

Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer.

DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply. Remember to flush the line prior to installing the saddle.

The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI. If your water pressure exceeds 90 PSI at anytime, a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid.

A water shut-off valve should be installed on the incoming water line in a convenient location (Use a low restriction type valve, such as a 1/4-turn ball valve, to avoid loss of water flow thru the valve.

The provided water line strainer must be installed in the supply line, between the shutoff valve and inlet fitting. Note FLOW arrow marking on strainer body.

4

Image 6
Contents Pour Over Automatic Units With FaucetWarranty Statement Shipping Damage Claims ProcedureTable of Contents SpecificationsFeatures and Operating Controls Precautions and General Information Agency Approval InformationInstallation Instructions PLUMBER’S Installation InstructionsLeveling the Unit Installation Instructions ELECTRICIAN’S Installation InstructionsOperation START-UPPOUR-OVER Feature Automatic OperationHOT Water Faucet Brewing Coffee PreparationPOUR-OVER Operation Procedure Clean Coffee Brewer Cleaning InstructionsTroubleshooting Suggestions Symptom Possible Cause Suggested RemedyAccess Panels Servicing InstructionsTemperature Adjustment Servicing InstructionsReplace Thermostat Timer AdjustmentRemove Tank LID Assembly Replace Heating ElementReplace Solenoid OLD-STYLEReplace Timer Assembly Replace HOT Water Faucet CoilRepair HOT Water Faucet Procedure Delime the Water Tank Servicing Instructions Exploded View & Parts List Cabinet & Related ComponentsDescription Used on HOT Water Tank Assembly Description Used onElectrical Components Description Used onInternal Plumbing Components Faucet Repair KitsWiring Diagrams Wiring Diagram Wiring Diagram