Emerson Process Management 396PVP Essential Instructions, Hazardous Area Installation

Page 2

ESSENTIAL INSTRUCTIONS

READ THIS PAGE BEFORE PROCEEDING!

Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety pro- gram when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following sit- uations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation.

Read all instructions prior to installing, operating, and servicing the product. If this Instruction Manual is not the correct manual, telephone 1-800-654- 7768 and the requested manual will be provided. Save this Instruction Manual for future reference.

If you do not understand any of the instructions, contact your Rosemount representative for clarification.

Follow all warnings, cautions, and instructions marked on and supplied with the product.

Inform and educate your personnel in the proper installation, operation, and maintenance of the product.

Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources.

To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.

When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and proce- dures can affect the product’s performance and place the safe operation of your process at risk. Look alike substitutions may result in fire, electrical hazards, or improper operation.

DANGER

HAZARDOUS AREA

INSTALLATION

This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammable liquids or in hazardous area locations must be carefully eval- uated by qualified on site safety personnel.

To secure and maintain an intrinsically safe installation, an appropriate transmitter/ safety barrier/sensor combination must be used. The installation system must be in accordance with the governing approval agency (FM, CSA or BASEEFA/CENELEC) hazardous area classifi- cation requirements. Consult your analyzer/ transmitter instruction manual for details.

Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the responsibility of the user.

CAUTION

SENSOR/PROCESS

APPLICATION COMPATIBILITY

The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibility of the user.

About This Document

This manual contains instructions for installation and operation of the Models 396P and 396PVP TUpH Combination pH/ORP Sensors. The following list provides notes concerning all revisions of this document.

Rev. Level

Date

Notes

08/95-2/01 This is the initial release of the product manual. The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering.

A12/01 Added wiring diagram to page 14.

B4/02 Revised drawings on pages 6, 7, and 14.

C7/02 Added 1055 wiring diagrams.

D8/03 Added Silcore information.

E5/04 Added 5081 and Xmt wiring info. Deleted obsolete model information.

G11/05 Changed Figure 4-6 drawing on page 17. Resized Figure 1-1 drawing on page 2.

H3/06 Changed PN on Fig. 2-5, page 8, and in Table 7-3, page 29. Added a note on page 11.

Emerson Process Management

Liquid Division

2400 Barranca Parkway

Irvine, CA 92606 USA

Tel: (949) 757-8500

Fax: (949) 474-7250

http://www.raihome.com

© Rosemount Analytical Inc. 2006

Image 2
Contents Combination pH/ORP Sensor Hazardous Area Installation Essential InstructionsModel 396P and 396PVP Combination pH/ORP Sensor List of Figures Section Description and Specifications Features and ApplicationsSpecifications Percent LinearityRecommended Accessories for First Time Installations Ordering InformationOther Accessories for Models 396P and 396PVP Part DescriptionMounting Section InstallationUnpacking and Inspection Dimensional Drawing 40396P0140396P02 40396P03 40396P04Low Flow Cell PN Section Wiring Model 396P-01 Wiring Matrix GuideWire Functions for Model 396P with and without Preamplifier 40396P15 40396P13 40396P08 Section Section Wiring Models 396P-02 and 396PVP Refer toConnector Pins Their Functions Section Section Section 20. Wiring to Model 54e pH/ORP With Variopol 40396P25 40396P2423. Wiring Model 396P-01 to Model Xmt-P-HT-10 Section Start UP and Calibration ORP CalibrationCompensation Elements Section MaintenanceAutomatic Temperature Compensator ElementsModel 396P and 396PVP ORP Description of Problem Remedy Section Diagnostics and TroubleshootingDiagnostic Message UG!1SSTroubleshooting Without Advanced Diagnostics Description Quantity Section Return of Material Warranty RepairNON-WARRANTY Repair GeneralWarranty Return of MaterialSpecifications subject to change without notice

396P, 396PVP specifications

Emerson Process Management has established itself as a leader in the automation industry, providing innovative solutions that enhance operational efficiencies and improve process control. Among its notable offerings are the 396PVP and 396P pressure transmitters, designed to meet the needs of various industrial applications.

The 396PVP model is equipped with advanced features that facilitate high-performance measurements in both challenging and standard environments. This pressure transmitter utilizes a piezoresistive sensor, allowing for accurate and reliable pressure readings. It supports a wide range of measurement capabilities, making it suitable for liquids, gases, and vapors across diverse industries. With an impressive pressure range, the 396PVP caters to various applications, from HVAC systems to more demanding scenarios in oil and gas extraction.

In terms of technology, the 396PVP leverages digital communication protocols, including HART and FOUNDATION Fieldbus, enabling seamless integration into existing control systems. This capability not only enhances data transmission but also facilitates remote monitoring and diagnostics, significantly reducing downtime and maintenance requirements. The transmitter is also designed with an intuitive interface, allowing for straightforward configuration and calibration via handheld devices or software.

On the other hand, the 396P model offers exceptional performance for demanding pressure measurement requirements. It features robust construction materials that ensure durability and resistance to harsh environments, making it an ideal choice for applications in chemical processing and power generation. The 396P is designed with a fast response time, ensuring real-time data accuracy, which is critical for maintaining process integrity and safety.

Both models showcase Emerson's commitment to safety and reliability. They are built to meet stringent industry standards, which guarantees quality performance in hazardous locations. Furthermore, the embedded diagnostic features provide real-time health monitoring, alerting operators of any potential issues before they escalate, thereby safeguarding operations.

In summary, the 396PVP and 396P pressure transmitters from Emerson Process Management exemplify cutting-edge technology and high-quality engineering. With their advanced sensing capabilities, robust design, and integration-friendly features, these transmitters are essential tools for optimizing process control and enhancing overall productivity in various industrial settings. Whether it's for precise measurements in a chemical plant or reliable pressure readings in an oil field, the 396 series offers the performance and durability required to thrive in today's demanding operational landscapes.