Emerson Process Management 396PVP instruction manual List of Figures

Page 4

MODEL 396P and 396PVPTABLE OF CONTENTS

LIST OF FIGURES

Number

Title

Page

1-1

Cross Section Diagram of the TUpH Patented Reference Technology

2

2-1

Dimensional Drawing

6

2-2

Flow-Through Tee with Adapter (PN 915240-xx)

6

2-3

Flow-Through and Insertion Installations

7

2-4

Model 396P/396PVP with Insertion Mounting Adapter (PN 23242-02)

7

2-5

Submersion Installations

8

2-6

Low Flow Cell PN 23728-00

9

2-7

Jet Spray Cleaner PN 12707-00

10

3-1

Wire Functions for Model 396P with & without Preamplifier

10

3-2

Wiring Details Model 396P-01-50 for use with & without Junction Box (PN 22719-02) for Models 1181, 1050, & 1060 ....

12

3-3

Wiring Details Model 396P-01-54 for use with & sithout Junction Box (PN 22719-02) for Models 1054/A/B, 2054, 2081

 

 

and Extension Cable (PN 9200254)

13

3-4

Wiring Details Model 396P-01-55 for use with Junction Box (PN 23550-00) for Models 54, 3081, 4081, 81, and 5081 ...

14

3-5

Wiring Details Model 396P-01-55 for use with Models 54, 81, 3081, 4081, and 5081

15

3-6

Wiring Model 396P-01)-( )-55 Sensor to Model 1055-10-22-32 Analyzer

15

4-1

Wire Functions for Mating Variopol Cable used with Model 396PVP

17

4-2

Connector Pins and their Functions

17

4-3

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Model 81

17

4-4

Wiring Details for Models 396PVP or 396P-02-50 with Mating Variopol Cable (PN 23645-07) for use with Model 1181 ...

17

4-5

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-07) for use with Model 2081 ...

17

4-6

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Models 3081,

 

 

4081, and 5081

17

4-7

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Remote

 

 

Junction Box (PN 23555-00) to Model 81

18

4-8

Wiring Details for Models 396PVP or 396P-02-50 with Mating Variopol Cable (PN 23645-07) for use with Remote

 

 

Junction Box (PN 23309-03) to Model 1181

18

4-9

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Model 54

18

4-10

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Remote

 

 

Junction Box (PN 23555-00) to Model 54

18

4-11

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-06) for use with Remote

 

 

Junction Box (PN 23309-03) to Model 2081

19

4-12

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Remote

 

 

Junction Box (PN 23555-00) to Models 3081 and 4081

19

4-13

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-07) for use with Model 1054 ...

19

4-14

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-07) for use with

 

 

Model SCL-(P/Q)

19

4-15

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Model 1055 ...

20

4-16

Wiring Model 396P-(02)-( )-54/55-(61) Sensor to Model 1055-01-10-22-32 Analyzer

20

4-17

Wiring Details for Models 396PVP or 396P-02-55 with Mating Variopol Cable (PN 23645-07) for use with Remote

 

 

Junction Box (PN 23557-00) to Model 1055

20

4-18

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-06) for use with Models

 

 

1054A/B and 2054

21

4-19

Wiring Details for Models 396PVP or 396P-02-54 with Mating Variopol Cable (PN 23645-06) for use with Remote

 

 

Junction Box (PN 23309-04) to Models 1054A/B and 2054

21

4-20

Wiring to Model 54e pH/ORP with Variopol

21

4-21

Wiring Details Model 396P-02-50 for use with Junction Box (PN 23309-03), Remote Preamplifier, and Extension

 

 

Cable (PN 9200254)

22

4-22

Wiring Details Model 396P-02-54 for use with Junction Box (PN 23309-04), Remote Preamplifier (PN 22698-03), and ..

 

 

Extension Cable (PN 9200254)

22

4-23

Wiring Model 396P-01 to Model Xmt-P-HT-10

23

4-24

Wiring Models 396P-02 and 396PVP to Model Xmt-P-HT-10

23

ii

Image 4
Contents Combination pH/ORP Sensor Hazardous Area Installation Essential InstructionsModel 396P and 396PVP Combination pH/ORP Sensor List of Figures Section Description and Specifications Features and ApplicationsSpecifications Percent LinearityRecommended Accessories for First Time Installations Ordering InformationOther Accessories for Models 396P and 396PVP Part DescriptionUnpacking and Inspection Section InstallationMounting Dimensional Drawing 40396P0140396P02 40396P03 40396P04Low Flow Cell PN Section Wiring Model 396P-01 Wiring Matrix GuideWire Functions for Model 396P with and without Preamplifier 40396P15 40396P13 40396P08 Section Section Wiring Models 396P-02 and 396PVP Refer toConnector Pins Their Functions Section Section Section 20. Wiring to Model 54e pH/ORP With Variopol 40396P25 40396P2423. Wiring Model 396P-01 to Model Xmt-P-HT-10 Section Start UP and Calibration ORP CalibrationSection Maintenance Automatic Temperature CompensatorCompensation Elements ElementsModel 396P and 396PVP ORP Section Diagnostics and Troubleshooting Diagnostic MessageDescription of Problem Remedy UG!1SSTroubleshooting Without Advanced Diagnostics Description Quantity Warranty Repair NON-WARRANTY RepairSection Return of Material GeneralWarranty Return of MaterialSpecifications subject to change without notice

396P, 396PVP specifications

Emerson Process Management has established itself as a leader in the automation industry, providing innovative solutions that enhance operational efficiencies and improve process control. Among its notable offerings are the 396PVP and 396P pressure transmitters, designed to meet the needs of various industrial applications.

The 396PVP model is equipped with advanced features that facilitate high-performance measurements in both challenging and standard environments. This pressure transmitter utilizes a piezoresistive sensor, allowing for accurate and reliable pressure readings. It supports a wide range of measurement capabilities, making it suitable for liquids, gases, and vapors across diverse industries. With an impressive pressure range, the 396PVP caters to various applications, from HVAC systems to more demanding scenarios in oil and gas extraction.

In terms of technology, the 396PVP leverages digital communication protocols, including HART and FOUNDATION Fieldbus, enabling seamless integration into existing control systems. This capability not only enhances data transmission but also facilitates remote monitoring and diagnostics, significantly reducing downtime and maintenance requirements. The transmitter is also designed with an intuitive interface, allowing for straightforward configuration and calibration via handheld devices or software.

On the other hand, the 396P model offers exceptional performance for demanding pressure measurement requirements. It features robust construction materials that ensure durability and resistance to harsh environments, making it an ideal choice for applications in chemical processing and power generation. The 396P is designed with a fast response time, ensuring real-time data accuracy, which is critical for maintaining process integrity and safety.

Both models showcase Emerson's commitment to safety and reliability. They are built to meet stringent industry standards, which guarantees quality performance in hazardous locations. Furthermore, the embedded diagnostic features provide real-time health monitoring, alerting operators of any potential issues before they escalate, thereby safeguarding operations.

In summary, the 396PVP and 396P pressure transmitters from Emerson Process Management exemplify cutting-edge technology and high-quality engineering. With their advanced sensing capabilities, robust design, and integration-friendly features, these transmitters are essential tools for optimizing process control and enhancing overall productivity in various industrial settings. Whether it's for precise measurements in a chemical plant or reliable pressure readings in an oil field, the 396 series offers the performance and durability required to thrive in today's demanding operational landscapes.