Emerson Process Management 396PVP Wire Functions for Model 396P with and without Preamplifier

Page 15

MODEL 396P and 396PVP

Wiring. The Model 396P has an optional built-in pre- amplifier and is offered with a shielded cable. The cable should be handled carefully and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent it from being twisted, dam- aged or scraped by rough, sharp edges or surfaces. Please refer to Figures 3-1 through 3-6 for wiring Model 396P-01.

SECTION 3.0

WIRING - MODEL 396P

DANGER

DO NOT CONNECT SENSOR CABLE TO POWER LINES. SERIOUS INJURY MAY RESULT.

NOTE

Remove electrical tape or shrink sleeve from gray reference wire before connecting wire to terminal.

Model 396P Option 01 (with preamplifier) cable

Model 396P Option 02 (without preamplifier) cable

FIGURE 3-1. Wire Functions for Model 396P with and without Preamplifier

11

Image 15
Contents Combination pH/ORP Sensor Essential Instructions Hazardous Area InstallationModel 396P and 396PVP Combination pH/ORP Sensor List of Figures Features and Applications Section Description and SpecificationsPercent Linearity SpecificationsOrdering Information Recommended Accessories for First Time InstallationsPart Description Other Accessories for Models 396P and 396PVPSection Installation Unpacking and InspectionMounting 40396P01 Dimensional Drawing40396P02 40396P04 40396P03Low Flow Cell PN Wiring Matrix Guide Section Wiring Model 396P-01Wire Functions for Model 396P with and without Preamplifier 40396P15 40396P13 40396P08 Section Refer to Section Wiring Models 396P-02 and 396PVPConnector Pins Their Functions Section Section Section 20. Wiring to Model 54e pH/ORP With Variopol 40396P24 40396P2523. Wiring Model 396P-01 to Model Xmt-P-HT-10 ORP Calibration Section Start UP and CalibrationElements Section MaintenanceAutomatic Temperature Compensator Compensation ElementsModel 396P and 396PVP ORP UG!1SS Section Diagnostics and TroubleshootingDiagnostic Message Description of Problem RemedyTroubleshooting Without Advanced Diagnostics Description Quantity General Warranty RepairNON-WARRANTY Repair Section Return of MaterialReturn of Material WarrantySpecifications subject to change without notice

396P, 396PVP specifications

Emerson Process Management has established itself as a leader in the automation industry, providing innovative solutions that enhance operational efficiencies and improve process control. Among its notable offerings are the 396PVP and 396P pressure transmitters, designed to meet the needs of various industrial applications.

The 396PVP model is equipped with advanced features that facilitate high-performance measurements in both challenging and standard environments. This pressure transmitter utilizes a piezoresistive sensor, allowing for accurate and reliable pressure readings. It supports a wide range of measurement capabilities, making it suitable for liquids, gases, and vapors across diverse industries. With an impressive pressure range, the 396PVP caters to various applications, from HVAC systems to more demanding scenarios in oil and gas extraction.

In terms of technology, the 396PVP leverages digital communication protocols, including HART and FOUNDATION Fieldbus, enabling seamless integration into existing control systems. This capability not only enhances data transmission but also facilitates remote monitoring and diagnostics, significantly reducing downtime and maintenance requirements. The transmitter is also designed with an intuitive interface, allowing for straightforward configuration and calibration via handheld devices or software.

On the other hand, the 396P model offers exceptional performance for demanding pressure measurement requirements. It features robust construction materials that ensure durability and resistance to harsh environments, making it an ideal choice for applications in chemical processing and power generation. The 396P is designed with a fast response time, ensuring real-time data accuracy, which is critical for maintaining process integrity and safety.

Both models showcase Emerson's commitment to safety and reliability. They are built to meet stringent industry standards, which guarantees quality performance in hazardous locations. Furthermore, the embedded diagnostic features provide real-time health monitoring, alerting operators of any potential issues before they escalate, thereby safeguarding operations.

In summary, the 396PVP and 396P pressure transmitters from Emerson Process Management exemplify cutting-edge technology and high-quality engineering. With their advanced sensing capabilities, robust design, and integration-friendly features, these transmitters are essential tools for optimizing process control and enhancing overall productivity in various industrial settings. Whether it's for precise measurements in a chemical plant or reliable pressure readings in an oil field, the 396 series offers the performance and durability required to thrive in today's demanding operational landscapes.