Emerson Process Management 396PVP instruction manual Ordering Information

Page 7

MODEL 396P and 396PVP

SECTION 1.0

 

DESCRIPTIONS AND SPECIFICATIONS

1.3 ORDERING INFORMATION

The Model 396P Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation. The sensor includes a general purpose pH electrode or a platinum ORP electrode, a patented reference junction and a solution ground. The Model 396P comes standard with a recessed electrode; an optional slotted tip is also available. In addition, the 396P features an optional integral hermetically sealed preamplifier and 15 ft or 25 ft cable lengths. Automatic temperature compensation, Pt 100 or 3K Balco, is standard with the Model 396P.

The Model 396P insertion/submersion sensor with integral cable is offered with or without a built-in preamplifier

MODEL

396P TUpH INSERTION/SUBMERSION POLYPROPYLENE pH/ORP SENSOR

CODE

PREAMPLIFIER/CABLE (Required Selection)

01With integral preamplifier, 25 ft cable

02Without integral preamplifier, 15 ft cable

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10

GPLR hemi bulb, General Purpose Low Resistivity (0-14 pH)

12ORP

13GPLR flat bulb, General Purpose Low Resistivity (2 - 13 pH)

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

50

For Models 1181 (3K TC)

54For Models 1054A/B, 2054, 2081 (Pt 100 RTD)

55For Models 54e, 3081, 81, 4081, 1055, 5081, Xmt (PT-100 RTD)

CODE

OPTIONAL SELECTION

 

41

Slotted Tip (not available on flat bulb sensors)

 

396P -

01 - 10 - 55

EXAMPLE

 

 

 

NOTE: The Model 396P is also compatible with Model SCL-P/Q (option 02-54 only).

TABLE 1-1. RECOMMENDED ACCESSORIES FOR FIRST TIME INSTALLATIONS

1. Mounting Accessories (optional)

Choose one: PN

915240-03, PVC flow through tee, 3/4 in. NPT process connection

PN

915240-04, PVC flow through tee, 1 in. NPT process connection

PN

915240-05, PVC flow through tee, 1-1/2 in. NPT process connection

PN

23728-00, acrylic low flow cell

PN

2002011, 1-1/2 in. CPVC tee with 1-in. FNPT connection

PN

11275-01, sensor handrail assembly

2. Junction Boxes (optional)

Remote Junction Boxes (used with option -02 sensors, for sensor to analyzer distances of more than 15 ft) Choose one: PN 23555-00 includes preamplifier for Models 54, 81, 3081, 4081, 5081, Xmt

PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer

PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054A/B series, 2054, 2081 Analyzers Choose one: PN 9120516 BNC Adapter for use with remote junction boxes PNs 23309-03, 23309-04

Remote Junction Box (used with option -01 sensors)

Choose one: PN 23550-00 cable extension board

3. Extension cables (used with remote junction boxes)

Choose one: PN 23646-01, 11 conductor, shielded, prepped

PN 9200273, 11 conductor, shielded, unprepped

3

Image 7
Contents Combination pH/ORP Sensor Essential Instructions Hazardous Area InstallationModel 396P and 396PVP Combination pH/ORP Sensor List of Figures Features and Applications Section Description and SpecificationsPercent Linearity SpecificationsOrdering Information Recommended Accessories for First Time InstallationsPart Description Other Accessories for Models 396P and 396PVPUnpacking and Inspection Section InstallationMounting 40396P01 Dimensional Drawing40396P02 40396P04 40396P03Low Flow Cell PN Wiring Matrix Guide Section Wiring Model 396P-01Wire Functions for Model 396P with and without Preamplifier 40396P15 40396P13 40396P08 Section Refer to Section Wiring Models 396P-02 and 396PVPConnector Pins Their Functions Section Section Section 20. Wiring to Model 54e pH/ORP With Variopol 40396P24 40396P2523. Wiring Model 396P-01 to Model Xmt-P-HT-10 ORP Calibration Section Start UP and CalibrationElements Section MaintenanceAutomatic Temperature Compensator Compensation ElementsModel 396P and 396PVP ORP UG!1SS Section Diagnostics and TroubleshootingDiagnostic Message Description of Problem RemedyTroubleshooting Without Advanced Diagnostics Description Quantity General Warranty RepairNON-WARRANTY Repair Section Return of MaterialReturn of Material WarrantySpecifications subject to change without notice

396P, 396PVP specifications

Emerson Process Management has established itself as a leader in the automation industry, providing innovative solutions that enhance operational efficiencies and improve process control. Among its notable offerings are the 396PVP and 396P pressure transmitters, designed to meet the needs of various industrial applications.

The 396PVP model is equipped with advanced features that facilitate high-performance measurements in both challenging and standard environments. This pressure transmitter utilizes a piezoresistive sensor, allowing for accurate and reliable pressure readings. It supports a wide range of measurement capabilities, making it suitable for liquids, gases, and vapors across diverse industries. With an impressive pressure range, the 396PVP caters to various applications, from HVAC systems to more demanding scenarios in oil and gas extraction.

In terms of technology, the 396PVP leverages digital communication protocols, including HART and FOUNDATION Fieldbus, enabling seamless integration into existing control systems. This capability not only enhances data transmission but also facilitates remote monitoring and diagnostics, significantly reducing downtime and maintenance requirements. The transmitter is also designed with an intuitive interface, allowing for straightforward configuration and calibration via handheld devices or software.

On the other hand, the 396P model offers exceptional performance for demanding pressure measurement requirements. It features robust construction materials that ensure durability and resistance to harsh environments, making it an ideal choice for applications in chemical processing and power generation. The 396P is designed with a fast response time, ensuring real-time data accuracy, which is critical for maintaining process integrity and safety.

Both models showcase Emerson's commitment to safety and reliability. They are built to meet stringent industry standards, which guarantees quality performance in hazardous locations. Furthermore, the embedded diagnostic features provide real-time health monitoring, alerting operators of any potential issues before they escalate, thereby safeguarding operations.

In summary, the 396PVP and 396P pressure transmitters from Emerson Process Management exemplify cutting-edge technology and high-quality engineering. With their advanced sensing capabilities, robust design, and integration-friendly features, these transmitters are essential tools for optimizing process control and enhancing overall productivity in various industrial settings. Whether it's for precise measurements in a chemical plant or reliable pressure readings in an oil field, the 396 series offers the performance and durability required to thrive in today's demanding operational landscapes.