Bunn STA, STFA, SA service manual SERVICE cont TANK HEATER

Page 20
SERVICE (cont.)

SERVICE (cont.)

TANK HEATER

P1592

FIG. 12 TANK HEATER

Location:

The tank heater is located inside the tank and secured to the tank bottom.

Test Procedures:

1.Disconnect the brewer from the power supply.

2.Check the voltage across the black and white wires on 100 or 120 volt models or the black and red wires for 120/240 volt models, 200 volt models and 240 volt models with a voltmeter. Connect the brew to the power source. The indication must be:

a)120 volts ac for two wire 120 volt 15 and 20 amp models .

b)240 volts ac for three wire 120/240 volt models.

c)200 to 240 volts ac for two wire 200 or 240 volt models.

d)100 volts ac for two wire 100 volt models.

3.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4

If voltage is not present as described, refer to the Wiring Diagrams and check wiring harness.

4.Disconnect the black wire and the white wire or red wire from the tank heater terminals.

5.Check for continuity across the tank heater termi- nals.

If continuity is present as described, reconnect the wires, the tank heater is operating properly.

If continuity is not present as described, replace the tank heater.

NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath.

Removal and Replacement:

1.Remove top cover or top warmer housing as prevoiusly described.

2.Disconnect the water supply tube from the sole- noid.

3.On brewers with faucet, disconnect the faucet.

4.Remove sprayhead and the hex nut securing the sprayhead tube to the hood. Set aside for reas- sembly.

5.Disconnect the wire from the tank level probe.

6.Remove the thermostat capillary bulb as de- scribed in section for control thermostat.

7.Disconnect the wires from the limit thermostat.

Page 20

29251 052500

 

Image 20
Contents POST OFFICE BOX SPRINGFIELD, ILLINOIS FAXBUNN S,SA ST,STA STF,STFAWARRANTY USER NOTICESUSER NOTICES Continued #00656.0000#00882.0000 #02763.0000 #02765.0000 #02769.0000ELECTRICAL REQUIREMENTS PLUMBING REQUIREMENTSElectrical Hook-Up Models S & SAINITIAL SET-UP 4A. Models S & SA4B. Models ST, STA 4C. Models STF & STFACLEANING Models ST, STF, STA & STFA ON/OFF SWITCHSTART SWITCH OPERATING CONTROLSTROUBLESHOOTING TROUBLESHOOTING cont PROBLEMPROBABLE CAUSE REMEDYTROUBLESHOOTING cont PROBLEM Dripping from sprayhead Beverage overflows dispenser cont Weak beverage Brewer is making unusal noises Contents SERVICECOMPONENT ACCESS SERVICE cont CONTROL THERMOSTATSERVICE cont CONTROL THERMOSTAT cont SERVICE cont LIMIT THERMOSTAT ON/OFF SWITCH Models ST, STA, STF & STFA FIG. 8 SOLENOID START SWITCH Models ST, STA, STF & STFA SERVICE cont TANK HEATER SERVICE cont TANK HEATER Cont FIG. 14 BREW TIMER SERVICE cont BREW TIMER Early Modelscont DIGITAL BREW TIMER Late Models FIG. 16 DIGITAL BREW TIMERSERVICE cont DIGITAL BREW TIMER Late Modelscont LIQUID LEVEL CONTROL BOARD Models STF & STFA STFACont SERVICE cont TIMER RELAY Models STF & STFA SERVICE cont WARMER ELEMENTS SERVICE cont THERMAL CUT-OFFModels SA, STA & STFA Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251Page 29251