Bunn SA, STA, STFA service manual TROUBLESHOOTING cont PROBLEM, Probable Cause, Remedy

Page 9

TROUBLESHOOTING (cont.)

PROBLEM

Inconsistent beverage level in dis- penser (cont.)

Consistently low beverage level in the dispenser (ST, STF, STA & STFA)

Spitting or excessive steaming

PROBABLE CAUSE

3.Syphon system

4.Lime build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

5.Water pressure (ST, STF, STA & STFA)

1. Timer

2.Strainer/flow control (.222 GPM)

1. Lime build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

2. Control thermostat

REMEDY

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

The water pressure to the brewer must be at least 20 psi (138 kPa).

(A)Early models-Timer dial must indicate at least two minutes and fifteen seconds.

(B)Refer to Service - Digital Timer for testing procedures. See page 24

(A)Direction of flow arrow must be pointing towards brewer.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

Inspect tank assembly for exces- sive lime deposits. Delime as re- quired.

Refer to Service - Control Ther- mostat for testing procedures. See page 14

Page 9

29251 052500

 

Image 9
Contents FAX POST OFFICE BOX SPRINGFIELD, ILLINOISBUNN S,SA ST,STA STF,STFAUSER NOTICES WARRANTY#00656.0000 USER NOTICES Continued#00882.0000 #02763.0000 #02765.0000 #02769.0000PLUMBING REQUIREMENTS ELECTRICAL REQUIREMENTSElectrical Hook-Up Models S & SA4A. Models S & SA INITIAL SET-UP4B. Models ST, STA 4C. Models STF & STFAModels ST, STF, STA & STFA ON/OFF SWITCH CLEANINGSTART SWITCH OPERATING CONTROLSTROUBLESHOOTING PROBLEM TROUBLESHOOTING contPROBABLE CAUSE REMEDYTROUBLESHOOTING cont PROBLEM Dripping from sprayhead Beverage overflows dispenser cont Weak beverage Brewer is making unusal noises SERVICE COMPONENT ACCESSContents CONTROL THERMOSTAT SERVICE contSERVICE cont CONTROL THERMOSTAT cont SERVICE cont LIMIT THERMOSTAT ON/OFF SWITCH Models ST, STA, STF & STFA FIG. 8 SOLENOID START SWITCH Models ST, STA, STF & STFA SERVICE cont TANK HEATER SERVICE cont TANK HEATER Cont FIG. 14 BREW TIMER SERVICE cont BREW TIMER Early Modelscont FIG. 16 DIGITAL BREW TIMER DIGITAL BREW TIMER Late ModelsSERVICE cont DIGITAL BREW TIMER Late Modelscont LIQUID LEVEL CONTROL BOARD Models STF & STFA STFACont SERVICE cont TIMER RELAY Models STF & STFA SERVICE cont WARMER ELEMENTS SERVICE cont THERMAL CUT-OFFModels SA, STA & STFA 29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page