SERVICE (cont.)
TANK HEATER (Cont.)
8.Disconnect the black wire and the white or red wire from the tank heater terminals.
9.Remove the three
10.Remove the tank lid with level probe.
11.Remove the switch panel and disconnect the leads to the tank "Keep Warm" heater.
12.On 100 volt models equipped with rear drain, open the
13.Direct the pink probe wire, capillary tube and top warmer wiring harness through the nylon bush- ing located on the rear of the basin flange.
14.Lift tank and fill basin assembly from housing and drain water from tank.
15.Remove the two hex nuts securing the tank heater to the bottom of tank. Remove tank heater with gaskets and discard.
16.Install new tank heater with gaskets to the tank and secure with two hex nuts.
17.Install tank with limit thermostat, sprayhead tube and tank heater.
18.Reconnect the inlet and outlet water lines to the solenoid and faucet.
19.Secure spayhead tube to hood using a hex nut.
20.Install sprayhead.
21.Reconnect the wires to the limit thermostat and control thermostat. See limit thermostat and control thermostat sections in this manual when reconnecting wires.
22.Install tank lid with holddown brackets and
23.Install the thermostat capillary bulb as described in section for control thermostat.
24.Reconnect the wire to the liquid level probe.
25.Refer to FIG. 13 when reconnecting the tank heater wires.
WHI or RED Wire
From Tank Heater
BLK Wire to Limit
Thermostat
P1593
FIG. 13 TANK HEATER TERMINALS
Page 21 | 29251 052500 |
|