Bunn STA, STFA, SA service manual SERVICE cont DIGITAL BREW TIMER Late Modelscont

Page 25
SERVICE (cont.)

SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)(cont.)

Timer Setting:

NOTE: Check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place, prior to setting or modifying volumes.

NOTE: All volume settings must be done with the sprayhead installed.

1.Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the "SET" position on the circuit board.

To increase a brew volume, place the ON/OFF switch in the "ON" position, press and hold the START switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.

To decrease a brew volume, place the ON/OFF switch in the "ON" position, press and release the START switch once for every two-second interval to be removed from the total brew time period; then imme- diately press and hold down the START switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved.

2.Setting brew volumes. To set a brew volume, first check that the SET/LOCK switch is in the "SET" position on the circuit board. Place the ON/OFF switch in the "ON" position, press and hold the START switch until three distinct clicks are heard and then release the switch. (Failure to release the switch within two sec- onds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory).

View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to "OFF".

NOTE: Several ounces of water will continue to syphon from the tank after turning the switch "OFF". The brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.

NOTE: When brewing coffee, volumes will decrease due to absorption by the coffee grounds.

3.Setting programming disable feature. If it be- comes necessary to prevent anyone from changing brew time once programmed, you can set the SET/ LOCK switch to the "LOCK" position. This will prevent any further programming.

NOTE: To relocate a rear-mounted digital brew timer to the front of the brewer, order kit number 32005.0000 for 120/240V 3-wire models. Order 32005.0001 for 200V-240V 2-wire models. These kits have the parts necessary to relocate the timer.

TL1 - WHI/RED to ON/OFF Switch

TL2 - WHI to Terminal Block and Warmer element (120V two-pole, 120/208V or 120/240V three pole terminal block) or

RED to Terminal Block and Warmer element (200V or 240V two pole ter- minal block)

TL3 - WHI/ORN to Start Switch (Top) TL4 - WHI/GRN to Solenoid Valve or Relay

Terminal B

TL5 - WHI/YEL to Start Switch (Bottom)

P2037

FIG. 17 DIGITAL TIMER WIRING

Page 25

29251 011501

 

Image 25
Contents FAX POST OFFICE BOX SPRINGFIELD, ILLINOISBUNN S,SA ST,STA STF,STFAUSER NOTICES WARRANTY#00656.0000 USER NOTICES Continued#00882.0000 #02763.0000 #02765.0000 #02769.0000PLUMBING REQUIREMENTS ELECTRICAL REQUIREMENTSElectrical Hook-Up Models S & SA4A. Models S & SA INITIAL SET-UP4B. Models ST, STA 4C. Models STF & STFAModels ST, STF, STA & STFA ON/OFF SWITCH CLEANINGSTART SWITCH OPERATING CONTROLSTROUBLESHOOTING PROBLEM TROUBLESHOOTING contPROBABLE CAUSE REMEDYTROUBLESHOOTING cont PROBLEM Dripping from sprayhead Beverage overflows dispenser cont Weak beverage Brewer is making unusal noises COMPONENT ACCESS SERVICEContents CONTROL THERMOSTAT SERVICE contSERVICE cont CONTROL THERMOSTAT cont SERVICE cont LIMIT THERMOSTAT ON/OFF SWITCH Models ST, STA, STF & STFA FIG. 8 SOLENOID START SWITCH Models ST, STA, STF & STFA SERVICE cont TANK HEATER SERVICE cont TANK HEATER Cont FIG. 14 BREW TIMER SERVICE cont BREW TIMER Early Modelscont FIG. 16 DIGITAL BREW TIMER DIGITAL BREW TIMER Late ModelsSERVICE cont DIGITAL BREW TIMER Late Modelscont LIQUID LEVEL CONTROL BOARD Models STF & STFA STFACont SERVICE cont TIMER RELAY Models STF & STFA SERVICE cont WARMER ELEMENTS SERVICE cont THERMAL CUT-OFFModels SA, STA & STFA 29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page29251 Page