TROUBLESHOOTING (cont.) |
|
|
|
|
PROBLEM | PROBABLE CAUSE |
| REMEDY | |
Brew cycle will not start (cont.) | 3. ON/OFF switch |
| Refer to Service - ON/OFF Switch | |
(ST, STF, STA & STFA) |
|
|
| for testing. See page 17 |
| 4. | Start switch |
| Refer to Service - Start Switch for |
|
|
|
| testing procedures. See page 19 |
| 5. | Timer |
| Refer to Service - Timer for testing |
|
|
|
| procedures. See page 22 or 24 |
| 6. | Solenoid valve |
| Refer to Service - Solenoid Valve |
|
|
|
| for testing procedures. See page |
|
|
|
| 18 |
| 7. | Strainer/flow control | (.222 | (A) Direction of flow arrow must |
| GPM) |
| be pointing towards brewer. |
(B) Remove the strainer/flow con- trol and check for obstructions. Clear or replace.
Water is not hot | 1. Limit thermostat |
| CAUTION - Do not eliminate or |
| bypass limit thermostat. Use only |
| BOM replacement part #29329. |
| 1000. |
Refer to Service - Limit Thermo- stat for testing procedures. See page 16
2. Control thermostat | Refer to Service - Control Ther- |
| mostat for testing procedures. See |
| page 14 |
Inconsistent beverage level in dis- penser
3. Tank heater
1.Strainer /flow control (.222 GPM) (ST, STF, STA & STFA)
Refer to Service - Tank Heater for testing procedures. See page 20
(A)Direction of flow arrow must be pointing towards the brewer.
(B)Remove the strainer/flow con- trol and check for obstruction. Clear or replace.
2. Liquid level board or level probe | Refer to Service - Liquid Level |
| Board for testing procedures. See |
| page 26 |
Page 8 | 29251 052500 |
|