Bunn JDF-4S manual Problem Probable Cause

Page 24

TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

Unit is not working

1. Step-down transformer.

Check for 120/24 or 230/24 vac. If no 24vac reading, replace step-down transformer.

 

2. Main control board.

If 24 vac present and no LED’s lit,

 

 

replace control board..

Difficulty brixing and/or weak bev-

1. Product viscosity or too cold.

Thorough thaw of product before

erage

 

use (35° - 40°)

 

2. Low water pressure.

Maintain 20 psi or higher and a

 

 

minimum flow rate of 3 fl oz/sec.

 

3. High water pressure.

Over 100 psi, install a pressure

 

 

regulator and set to 50 psi.

 

4. Dispense valve adjustment set-

A) Perform 3 second water dispense

 

ting.

test. Factory setting is 1.0 oz/sec.

 

 

Acceptable water flow rate is .-0.8

 

 

to 1.5 oz/sec depending on the mix

 

 

ratio (4+1).

 

 

B) Adjust water to proper mix ratio.

 

 

Once water is set, adjust motor

 

 

speed to achieve brix %.

 

5. Brix ratio.

Check for proper brix ratio per prod-

 

 

uct using Total Dispense method

 

 

and or refractometer method.

Difficulty brixing and/or weak bev-

1. Pump tubing.

Inspect, clean, or replace tubing

erage

 

and pump rotor/rollers for ease of

 

 

rotation.

 

2. Use of portable water pump.

A) Follow plumbing requirements

 

 

for pressure and flow rate.

 

 

B) Source another portable pump

 

 

or water supply that meets require-

 

 

ments.

Difficulty brixing bag-in-box

Vacuum leak

Inspect all lines and connections

 

 

from bag-in-box connector to bottle

 

 

adapter assembly.

24

39992 042007

 

Image 24
Contents JDF-2S JDF-4S Phone 217 529-6601 FAX 217Contents User Notices 27442.000000656.0000 12559.0003 33461.0001Initial SET-UP Electrical RequirementsPlumbing Requirements Electrical HOOK-UPDoor Cover Installation Install door coverSecure the door cover using 5 screws provided Plumbing Hookup Plumbing Connections JDF-2S Plumbing Connections JDF-4SInitial Fill Initial Fill Hose JDF-2S Initial Fill Hose JDF-4SInitial Fill Loading PrimingFrozen Concentrates Ambient Concentrates OptionalRefrigeration Switch Operating ControlsDispenser USE Operating Controls Portion Control OptionTemperature LEDs JDF-4S Cleaning & Preventive Maintenance Daily Rinse ProcedureDaily Parts Washing Weekly Semi-Automatic Sanitize ProcessCleaning Monthly Clean Condenser Coils Annually Replace Pump TubingOpen dispenser door Adjustment & Optional Settings Water Flow Testing and AdjustmentPump Speed Adjustment Mix RatioAdjustment & Optional Settings Temperature Compensated Refractometer MethodAdjustment & Optional Settings Dispenser Lockout Circuit Board LED Indicators JDF-2S Function ListLED # LED Color IlluminatesFunction List Circuit Board LED Indicators JDF-4S JDF-4STroubleshooting ProblemProbable Cause RemedyTroubleshooting Compressor ON/OFF switch Dirty condenser filter or finsRefrigeration Space around machine Problem Probable Cause Remedy Concentrate only Water onlyInitial fill/setup Nect fittingsTray Water pressure greater thanProblem Probable Cause Coolant Schematic Diagram Schematic Wiring Diagram JDF-2S Schematic Wiring Diagram JDF-4S Quick Setup Guide JDF-2S and JDF-4S JDF-2S shown Machine door