Bunn LCA-2A Corresponding Temperature Sensor, Evaporator temperature too high, Motor failure

Page 31

Troubleshooting (Continued)

Screen Displayed

 

Possible Cause

Troubleshooting Procedures

 

 

 

 

 

 

 

 

EVAP TEMP SENSOR

1.

Corresponding Temperature Sensor

Service Required

 

 

OUT OF RANGE

 

Probe wire(s) shorted to housing, or

 

 

 

 

 

 

 

 

to each other.

 

 

 

 

CHECK WIRE FOR

 

 

 

 

 

 

SHORTS

2.

Evaporator temperature too high.

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEFT PUMP FAULT!

1.

Motor failure

Service Required

 

 

CHK PUMP WIRING

2.

RPM Sensor failure

Service Required

 

 

 

 

 

 

 

CHK RPM SENSOR

 

 

 

 

 

 

CHK TUBING AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT PUMP FAULT!

1.

Motor failure

Service Required

 

 

CHK PUMP WIRING

2.

RPM Sensor failure

Service Required

 

 

 

 

 

 

 

CHK RPM SENSOR

 

 

 

 

 

 

CHK TUBING AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLER FAULT!

1.

Cabinet circulating fan failure

Service Required

 

 

EVAP TEMP TOO HI

2.

Ice build up on evaporator coils

Service Required

 

 

 

 

 

 

 

CHECK EVAP FAN

 

 

Service Required

 

 

CHK EVAP SENSOR

3.

Evaporator sensor failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING TIME

1.

Air intake filter clogged

Clean Air Filter

 

 

TOO LONG

2.

Wiring failure

Check wiring harness for breaks,

 

 

 

CHECK

AIR FILTER

 

 

shorts, open connectors

 

CHECK COOLING UNIT

3.

Compressor failure

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COND PROBE FAULT

1.

Concentrate buildup on probes

Check pump & tubing for proper

CHECK COND PROBES

 

 

installation. Clean probes

 

 

 

 

2.

Machine dispensing continously

Dispense

switch

failure,

Service

CHK DISP SWITCHES

 

 

Required

 

 

 

CHK CONNECTIONS

3.

Water flowing continously

Dispense

valve

leaking,

Service

 

 

 

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

JUMPER FAULT!

1. Invalid wire harness configuation

Service Required

 

 

CONFIG NOT VALID

 

 

 

 

 

 

CHECK J-18

ON CONTROL BOARD

31

34766.1 010313

 

Image 31
Contents Phone 217 529-6601 FAX 217 LCA-2 LCA-2A LCA-2 PC LCC-2BUNN-O-MATIC Commercial Product Warranty Introduction Contents40054.0000 00824.0002 47624.0000 User Notices00656.0001 37881.0000 28181.0003 11646.0002Electrical Requirements Field Wiring Terminal Block DiagramModels without Master ON/OFF Switch Models with Master ON/OFF SwitchElectrical HOOK-UP Plumbing RequirementsPlumbing HOOK-UP Initial SET-UP Installing the Drip Tray and Flip Down CUP Tray1513 Operating Controls and InterfaceOz/sec 16 I.D. Tubing Selecting the Correct Pump TubingDispense RateRemoving the restrictors Setting Dispenser Flow RateReprogramming the Dispenser Flow Rate Procedure for Adjusting the Mix Ratio to Taste Adjusting MIX RatiosRinse Alarm Feature FlavorGard FeatureAlarm Mode Brew Temperature Lockout Feature BIB Empty Lockout FeatureExit 3/16 Programming the DispenserMenu Screen Action Description Tank Temp 351 +0oz + LF Disp VolumeRT Disp Volume Menu Screen Lock Flavor ? Exit YES Flavors LockedCabinet Temp Menu Screen Tank TempExit + Ready TempCAL Left Pump ? Pull Dispense Menu ScreenRinse Time ? 12 Hrs + Action DescriptionCAL Right Side ? Exit YES Menu Screen ActionCAL Right Pump ? Pull Dispenser CAL RT WTR Flow Pull DispenserTest Refill ? Exit YES WTR Start DelayWTR Stop Delay Test LED’S ? No Exit YES Test Switches ?Initial Fill & Heat Priming the Concentrate Lines Loading the ConcentrateFilling Cambros or other large containers Operating the Pull & Hold DispenserModels LCA-2 PC, LCA-2C PC, LCA-2A PC Operating the Preset Portion Control DispenserWeekly Sanitizing Cleaning & Preventative MaintenanceGeneral Cleaning and Sanitizing Procedures Daily Rinsing Daily Parts WashingReplacing the Pump Tubing Preventive MaintenanceDraining the HOT Water Tank Power LED OFF TroubleshootingFront Panel LED Display Messages Left Refill LED on Internal FaultPossible Cause Troubleshooting Dispenser Diagnostics-LCD DisplayBIB Not properly connected Check BIB Connector Fittings Tubing kinked or blocked Check Tubing installationScreen Displayed Possible Cause Wiring failure Corresponding Temperature SensorEvaporator temperature too high Air intake filter clogged Clean Air FilterCalibrating the Left Side Dispenser Calibrating the Right Side Dispenser Field Calibrating the Hot Water Flow RateOz/sec 53 ml/sec w/ flow restrictor Oz/sec 74 ml/sec w/o flow restrictorCalibrating The Empty BIB Threshold Field Calibrating the Empty BIB WarningLCA-2/LCA-2, PC/LCA-2C/LCA-2C, PC/LCC-2/LCC-2C Schematic Wiring DiagramSchematic Wiring Diagram LCC-2A/LCA-2A/LCA-2A, PC