Bunn LCR-1, LCA-1 service manual Programming the Dispenser, LED Display, Display Mode Description

Page 12

PROGRAMMING THE DISPENSER

Two basic modes are available to the operator: Display Mode and Program Mode. Open the dispenser door to access the digital Programming Switches with LED display. To enter the Display Mode, Set the RUN/NIGHT/ PROGRAM Switch to the RUN position.

Display Mode: Used to view the current set-up values. Use the MENU switch to scroll to the next display.

NOTE: The display blanks out after two minutes of inactivity. Press any button to activate the display.

LED DISPLAY

180

0

1 8 0

1

3 0

2

0.0

3

0.0

4OFF

XX.X

DISPLAY MODE

DESCRIPTION

Home View

LCR-1 Alternates between the Tank and

 

Cabinet Temp.

 

LCA-1 Displays Tank Temp only.

Tank Temperature

Displays Target Tank Temperature (F°)

Dispense Ratio

Displays Dispense Ratio (XXX:1)

Portion Volume

Displays Portion Dispense Volume

 

(XX.X Oz.).

 

Set to 0.0 to Disable.

Dispense Total

Displays Total Coffee Concentrate

 

Dispensed (XX.X Gal)

Rinse Alarm (Hrs)

Displays The Number Of Hours

 

Between Required Rinses.

 

(Default = OFF, Alarm Disabled)

Software Version

Displays Software Version # -

 

Exits To Home View After 3 Seconds.

12

44806.1 081211

 

Image 12
Contents LCR-1 LCA-1 Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents User Notices 00656.000127442.0000 33461.0005 11646.0002Introduction Electrical RequirementsPlumbing Requirements Initial SET-UP Locating the DispenserPlumbing HOOK-UP Electrical HOOK-UPOperating Controls and Interface User InterfaceOperating Controls and Interface Installing Pump Tubing Installing the Pump TubingPriming the Concentrate Line Initial Fill & Heat Rinse Alarm Feature Cabinet Target Temperature LCR-1 OnlyLevel Selected Alarm Display Mode Description Programming the DispenserLED Display Program Mode Description Programming the DispenserOperating the Dispenser General Cleaning and Sanitizing Procedures Daily RinsingDaily Parts Washing Weekly SanitizingPreventive Maintenance Cleaning the AIR Filter LCR-1 OnlyReplacing the Pump Tubing Replacing the Water FilterCalibration Mode  DESCRIPTION Calibrating the DispenserReset Factory Defaults Default settingReset by holding the Decrease Calibrating the DispenserTroubleshooting Guide Error CodesLED Display Error Troubleshooting Guide Error Codes Follow errors codes apply to the LCR-1 onlyDESCRIPTION/TROUBLESHOOTING Calibration of the Concentrate Pump & Dispenser Flow Rate Calibrating the Concentrate PumpsCalibration of the Concentrate Pump & Dispenser Flow Rate Draining the HOT Water TankCalibrating the Dispenser Flow Rates Schematic Wiring Diagram LCR-1 / LCA-1 Tank Heater