Bunn LCA-1 Rinse Alarm Feature, Cabinet Target Temperature LCR-1 Only, Level Selected Alarm

Page 11

Rinse Alarm Feature

Periodic rinsing of the dispense tip is essential for proper maintenance and optimum performance of the dispenser. The automated Rinse Alarm feature has two levels of operation, Disabled and Warning.

Level Selected

Alarm

Disabled

None

Warning

Warning LED will come on 4 hrs prior to the selected time interval and remain on

 

until the Rinse procedure has been performed.

NOTE: Alarm Only - Does not prevent dispensing. To clear the Rinse Alarm, refer to the Rinse Procedure.

The dispenser is shipped with the automated Rinse Alarm disabled. It is up to the user to determine if the Rinse Alarm is needed and the time interval, based on their application and maintenance procedures. The time interval between Rinses is adjustable from 8 to 24 hrs. To enable the automated Rinse Alarm feature, refer to RINSE ALARM in Programming the Dispenser.

Rinse Procedure:

1.Open the cabinet door and select Rinse on the Selector switch – close the door.

2.Place a 2 Liter (1/2 Gal) container under the dispense tip.

3.Press and hold the Dispenser switch until water flow stops automatically, approximately 20 sec. NOTE: The Warning LED will turn OFF, when the Rinse procedure has been satisfied.

4.Open the cabinet door and select Normal on the Selector switch – close the door.

4

1

Cabinet Target Temperature (LCR-1 Only)

The LCR-1 is designed to “HOLD” Non-shelf stable concentrate at the desired Target Temperature. It is not designed to chill concentrate that has not been stored at or below the desired Target Temperature. NOTE: Always follow the concentrate Manufacturer’s recommendations for proper Storage and Shelf Life.

The LCR-1 Target Temperature is pre-set to 40° F (4° C) at the factory and can be adjusted from 35° to 75° F (2 - 24° C), see Calibrating the Dispenser to adjust the Target Temperature. NOTE: When operating temperatures are above 85° F (30° C), it may be necessary to lower the Target Temperature 5° to maintain the concentrate at the desired temperature. If ice starts to build up on the evaporator inside the cabinet, raise the Target Temperature a few degrees.

The Maximum Recommended Operating Temperature for the LCR-1 is 95° F (35° C).

11

44806.1 081211

 

Image 11
Contents Phone 217 529-6601 FAX 217 LCR-1 LCA-1BUNN-O-MATIC Commercial Product Warranty Contents 33461.0005 11646.0002 User Notices00656.0001 27442.0000Plumbing Requirements IntroductionElectrical Requirements Electrical HOOK-UP Initial SET-UPLocating the Dispenser Plumbing HOOK-UPUser Interface Operating Controls and InterfaceOperating Controls and Interface Priming the Concentrate Line Installing Pump TubingInstalling the Pump Tubing Initial Fill & Heat Level Selected Alarm Rinse Alarm FeatureCabinet Target Temperature LCR-1 Only LED Display Display Mode DescriptionProgramming the Dispenser Programming the Dispenser Program Mode DescriptionOperating the Dispenser Weekly Sanitizing General Cleaning and Sanitizing ProceduresDaily Rinsing Daily Parts WashingReplacing the Water Filter Preventive MaintenanceCleaning the AIR Filter LCR-1 Only Replacing the Pump TubingCalibrating the Dispenser Calibration Mode  DESCRIPTIONCalibrating the Dispenser Reset Factory DefaultsDefault setting Reset by holding the DecreaseLED Display Error Troubleshooting GuideError Codes DESCRIPTION/TROUBLESHOOTING Troubleshooting Guide Error CodesFollow errors codes apply to the LCR-1 only Calibrating the Concentrate Pumps Calibration of the Concentrate Pump & Dispenser Flow RateCalibrating the Dispenser Flow Rates Calibration of the Concentrate Pump & Dispenser Flow RateDraining the HOT Water Tank Tank Heater Schematic Wiring Diagram LCR-1 / LCA-1