TROUBLESHOOTING GUIDE
Error Codes
When an error has occurred, the Warning LED will be flashing. Open the door to view the LED Display and record the Error # shown on the display. Refer to the list of Error Codes below to identify the problem. The troubleshooting guide is provided to suggest probable causes and remedies for most problems. If the problem remains after exhausting the troubleshooting steps, contact the
LED DISPLAY
E_01
E_02
E_ 0 3
E_04
E_ 0 5
ERROR | DESCRIPTION/TROUBLESHOOTING |
Pump Error | Motor or RPM Sensor failure. Check |
| motor and RPM |
| Sensor wires for shorts, loose or open |
| connections. |
Heating Time Too Long | Tank Heater ON continuous for more |
| than 1 hour. |
| Check heater wires for loose or open |
| connections. |
Fill Time Too Long | Fill Valve ON continuous for more than |
| 15 minutes. |
| Water turned OFF. Refill Valve |
| disconnected or faulty. |
Tank Temp Sensor Error | Sensor reading Out Of Range (High |
| or Low). |
| Check Sensor wires for shorts, loose |
| or open connections. |
Dispense Time Too Long | Dispense or Hot Water switch has been |
| ON for more than 2 Min. |
| Check: Dispense switches for proper |
| operation or damage. Door harness |
| for shorts. |
19 | 44806.1 081211 |
|