Bunn LCA-2 LCC-2 manual Selecting the Correct Pump Tubing, Tube Selection Chart, Dispense, Rate

Page 7

SELECTING THE CORRECT PUMP TUBING

There are two pump tube sizes available for use with this dispenser. To determine the correct tubing for you application, first determine the dispenser flow rate you intend to use, refer to Setting Dispenser Flow Rate. Then look up the recommended tube size for the mix ratio of your concentrate, refer to the Tube Selection Chart.

TUBE SELECTION CHART

Dispense

Concentrate Ratios

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate

25

30

35

40

45

50

55

60

65

70

75

 

80

85

90

95

100

 

1.8 Oz/sec.

3/16" I.D. TUBING

 

 

 

 

1/8" I.D. TUBING

 

 

 

 

 

(53 ml/sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 Oz/sec.

3/16" I.D. TUBING

 

 

 

 

 

 

 

1/8" I.D. TUBING

 

 

 

(74 ml/sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Examples:

1.For a Dispenser Flow Rate of 2.5 Oz./sec (74 mL/sec) and a Mix Ratio of 35:1 – use 3/16" I.D. Tubing.

2.For a Dispenser Flow Rate of 1.8 Oz./sec (53 mL/sec) and a Mix Ratio of 60:1 – use 1/8" I.D. Tubing.

Tube kits can be purchased from BUNN-O-MATIC.

Part # 34727.1000 for 3/16" I.D. Tubing or #34728.1000 for 1/8" I.D. Tubing.

INSTALLING THE PUMP TUBING (Refer to the Tubing Installation Instructions in side the cabinet door for details.)

1.Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set it and the retainer plate aside.

2.Depress the tension screw and remove it from the notch in the pump body, releasing the spring tension on the pump band.

3.Apply lubricant (BUNN-O-MATIC part number M2548.1000) to the new pump tubing.

4.Insert the tubing onto the mix chamber port and wrap the tubing around the pump rotor, making sure that the elbow and clamps end up on the bottom side of the pump body.

5.Close the compression band reinsert the tension screw into the notch in the pump housing.

6.Replace the tubing retainer plate and tighten the thumbscrew.

7.Reconnect bag connector to the product box.

8.Repeat steps 1 through 7 for the other pump.

9.Prime the pumps. Refer to Priming the Concentrate Lines section.

Thumbscrew

2.0"

Tension Screw

2.0"

Lubricate between arrows

Remove Retaining Plate Release Spring Tension

Remove Tubing

Lubricate New Tube

Tension Screw

Tube Clamp

Install New Tubing

Completed Installation

7

34766 112502

 

Image 7
Contents Phone 217 529-6601 FAX 217 Post Office BOX SPRINGFIELD, IllinoisContents Introduction Optional Field WiringUser Notices Electrical Requirements Field Wiring Terminal Block DiagramPlumbing Requirements Electrical HOOK-UP Initial SET-UPPlumbing HOOK-UP Removing the restrictors Setting Dispenser Flow RateReprogramming the Dispenser Flow Rate Rate Tube Selection ChartSelecting the Correct Pump Tubing Dispense1513 Operating Controls and InterfaceInitial Fill & Heat FlavorGard Feature Brew Temperature Lockout Feature Rinse Alarm FeatureExit 3/16 Programming the Dispenser351 + SET RT Tube SizeReady Temp RT Disp VolumeLF Product Disp 0GAL RESET? RT Product Disp Enter PasswordRinse Time ? 12 Hrs + Action DescriptionCAL LF WTR Flow Pull Dispenser CAL Right Side ? Exit YES Menu Screen ActionCAL Right Pump ? Pull Dispenser CAL RT WTR Flow Pull DispenserMenu Screen WTR Start DelayWTR Stop Delay Factory Defaults No YES Action DescriptionPriming the Concentrate Lines Loading the ConcentrateOperating the Dispenser General Cleaning and Sanitizing Procedures Cleaning & Preventative MaintenanceReplacing the Pump Tubing Draining the HOT Water Tank Front Panel LED Display Messages TroubleshootingScreen Displayed Possible Cause Troubleshooting Dispenser DiagnosticsScreen Displayed 47 ml Calibrating the Left Side Dispenser22 ml Calibrating the Right Side Dispenser Field Calibrating the Empty BIB WarningOz/sec 53 ml/sec w/ flow restrictor Oz/sec 74 ml/sec w/o flow restrictorSchematic Wiring Diagram LCA-2, LCA-2C,LCC-2,LCC-2C Schematic Wiring Diagram LCC-2A/LCA-2A

LCA-2 LCC-2 specifications

The Bunn LCA-2 and LCC-2 are prominent models in the realm of commercial coffee brewing systems, known for their efficiency, reliability, and innovative technologies. Designed for coffee shops, restaurants, and catering services, these machines provide exceptional performance to meet the demands of high-volume coffee brewing.

One of the main features of both the LCA-2 and LCC-2 is their brewing capacity. The LCA-2 is capable of brewing up to 7.5 gallons of coffee per hour, while the LCC-2 can brew up to 13.5 gallons per hour. This high output makes them ideal for busy environments where quick service is essential. The machines are designed to brew directly into airpots or decanters, allowing for seamless service and easy coffee transportation.

Another standout characteristic is the precise water temperature control. The Bunn LCA-2 and LCC-2 utilize advanced brewing technology that ensures water is heated to the optimal temperature of 195°F to 205°F. This precision is crucial for maximizing flavor extraction and producing a quality cup of coffee consistently. Additionally, the machines feature an electronic brew timer, which allows users to regulate brewing time and ensure that every batch meets the desired flavor profile.

The build quality of these machines is also noteworthy. Constructed from durable stainless steel, the LCA-2 and LCC-2 are engineered to withstand the rigors of a commercial environment, assisting in maintaining consistent performance over time. Their sleek and professional design not only enhances the aesthetic appeal of any coffee service area but also facilitates easy cleaning and maintenance.

Furthermore, both models are equipped with a user-friendly control panel, providing operators with intuitive functionalities. The simple interface allows for quick adjustments, providing flexibility to customize brewing settings that suit different coffee varieties and customer preferences.

In terms of energy efficiency, the Bunn LCA-2 and LCC-2 are designed to minimize energy consumption without compromising performance. They feature a built-in tank that keeps water ready for brewing, drastically reducing the wait times between brews and ensuring that coffee is always available when needed.

In summary, the Bunn LCA-2 and LCC-2 stand out in the commercial coffee brewing segment, offering an impressive combination of high brewing capacity, precision temperature control, durable construction, and user-friendly operation. These features make them excellent choices for any establishment seeking to enhance their coffee service efficiently and effectively.