Bunn JDF-4SB, JDF-4D manual Transformer all Models, Transformer Terminals

Page 48
FIG. 69 TRANSFORMER

SERVICE (CONT.)

Transformer (all Models)

 

AC

A C

+

P3864

Location:

The transformer is located on the electrical com- ponent mounting bracket on the lower front of the dispenser behind the splash panel.

Test Procedure:

1.Disconnect the dispenser from the power source.

2.Check the voltage across black wire and the white wire from the main harness. Connect the dispenser to power source. The indication must be:

a)120 volts ac for two wire 120 volt models, three wire 120/208 volt and three wire 120/240 volt models.

b)240 volts ac for two wire 240 volt models.

c)230 volts ac for two wire 230 volt models.

4. Disconnect the dispenser from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the Wiring Diagrams and check the main wiring harness.

5.Check the voltage between J6-1 and J6-3 at the control board. Connect the dispenser to the power source. The indication must be 24 volts ac.

If voltage is present as described the transformer is operating properly.

If voltage is not present as described, replace the transformer.

Removal and Replacement:

1.Loosen the two #8-32 screws securing the com- ponent bracket to the dispenser housing base.

2.Pull component bracket out the front of the dispenser far enough so the transformer can be disconnected from the main wiring harness.

3Remove the two #6-32 keps nuts securing the transformer to the component bracket.

5.Remove and discard the transformer.

6.Install new transformer on the component bracket and secure with two #6-32 keps nuts.

7.Refer to Fig. 70 and connect the transformer to the main wiring harness.

8.Place the component bracket into position and tighten the two #8-32 screws.

 

WHI from

WHI/BLU to Control

Power Cord

Board J6-1,J12-1

BLK from

 

Power Cord

BLU

to Control

Board J6-3,J12-3

 

P1647

FIG. 70 TRANSFORMER TERMINALS

48

49179

110613

 

Image 48
Contents JDF-4D, JDF-4SB Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Introduction Recommended Daily Cleaning Instructions Required Regular Maintenance Problem Probable Cause Cold Water CirculationRemedy Problem Probable Cause Remedy RefrigerationDispenser Locked Out When dispensing. If yes, replace ContinuityEd replace relay Check for kinked flex lineConcentrate only Water onlyNect fittings TrayWater pressure greater than 100psiPump tubing Inspect, clean, or replace tubing Age Adapter assemblyUnit is not working Replace control boardService Component AccessServicecont Access Panels Access PanelsServicecont Dispense Platform Removal Dispense Platform RemovalService Test ProcedureBallast JDF-2S,4S LocationRemove the four screws attaching the fan and cover assembly Cabinet Fan all ModelsLG Compressor JDF-2S,4S,4D LocationCompressor Design Pressures High 335 Low 88 psiGD Compressor JDF-2S,4S,4D CompressorDisconnect and remove the transformer Compressor JDF-4SB Compressor ThermalBLU/BLK Compressor Switch all Models Compressor SwitchCondenser Fan all Models Condenser FANTest Procedure Power Supply Circuitry Control Board, Main all ModelsPortion Control Board JDF-2S,4S With a voltmeter, back probe check the voltageSource. The indication must be 24 volts ac To the transformer See TransformerPush Button Control Board JDF-4D Push Button Control BoardPortion Control Board JDF-4D Circulation Pump all Models With a voltmeterDispense Platform Switch all Models Disconnect the two black wires from the switchReturn power to the dispenser Dispense Pump all Models except JDF-4D Dispense PumpReconnect the two wires to the motor as shown in Fig Dispense Motor all ModelsDispense Valve all Models Dispense ValveDispense Switches JDF-2S, JDF-4S Dispense SwitchesCold Water Dispense Switch JDF-4S only Cold Water Dispense SwitchDispense Membrane Switch all Models LocationMembrane Switch EMI Filter all Models EMI FilterLamps, Holders and Ballasts Early Models Lamps & HoldersDisconnect power from the dispenser LED Lamps JDF-2S, JDF-4SLED regulator board Rectifier JDF-2S, JDF-4S RectifierRefer to to reconnect the wires Relay all ModelsVolts ac for 120 volt models Volts ac for 230 volt models Resistor all 230V Models ResistorSolenoid Cold Water JDF-4S only If voltage is present as described, proceed to #5Solenoid Inlet all Models 120V 1.2 kΩ 230V 3.84 kΩTemperature Probe all Models Temp Resistance Voltage32 F 31.2k 34k Ω 77 F 8k 10.2k ΩTemperature Sensor all Models 32 F 5k Ω77 F 350 Ω Transformer all Models Transformer TerminalsTransformer Lited Doors JDF-2S, JDF-4S Compressor Relay Q25 Water Q27Water Q28 Water Q7Diagram for JDF-2S LED Lited Doors Schematic Wiring Schematic Wiring Diagram JDF-4S Schematic Wiring Diagram JDF Schematic Wiring Diagram JDF-4D Schematic Wiring Diagram JDF-4D Electrical Schematic Diagram
Related manuals
Manual 28 pages 48.61 Kb Manual 28 pages 35.87 Kb Manual 31 pages 40.19 Kb

JDF-4D, JDF-4SB, JDF-4S specifications

The Bunn JDF-4S is a high-performance commercial coffee brewer designed to meet the needs of busy coffee shops, restaurants, and other establishments requiring a reliable and efficient coffee brewing solution. This versatile machine boasts an array of advanced features and technologies, making it a prominent choice among professionals in the coffee industry.

One of the most notable features of the Bunn JDF-4S is its ability to brew up to 4 gallons of coffee per hour, ensuring that establishments can keep pace with high-demand environments. This capacity makes it an ideal choice for venues that experience peak periods of coffee consumption, minimizing wait times for customers. The machine is designed with a multiple-brew option, allowing users to select various brew methods, which can cater to diverse customer preferences.

The JDF-4S incorporates Bunn’s patented brewing technology, which utilizes a precision-controlled process to ensure optimal flavor extraction. The brewed coffee is delivered at an ideal temperature, typically between 195°F and 205°F, promoting maximum taste and aroma. The machine also features a programmable digital controller that enables users to set specific brew times and adjust water temperature settings to achieve consistent results.

Another significant characteristic of the Bunn JDF-4S is its durability and ease of use. Constructed with high-quality materials, the machine is built to withstand the rigors of daily operation. The user-friendly interface features a simple touchpad design for easy navigation and programming. Additionally, the machine includes a built-in diagnostics program, helping users quickly identify and troubleshoot potential issues, thereby minimizing downtime.

The JDF-4S also offers flexible brewing options, including iced coffee brewing, enhancing its versatility. It is compatible with Bunn’s extensive range of coffee and tea dispensers, allowing businesses to expand their beverage offerings effortlessly. Furthermore, the unit features an easy-access water reservoir for quick refilling and reduced wait times during busy service periods.

In terms of maintenance, the Bunn JDF-4S is designed with user convenience in mind. The machine includes a rinse and clean cycle to ensure optimal hygiene and coffee quality. Integrated clean alerts guide users through the cleaning process, promoting regular upkeep and ensuring the longevity of the brewer.

In summary, the Bunn JDF-4S represents a cutting-edge solution for coffee brewing that prioritizes performance, versatility, and ease of use. With its advanced brewing technology, user-friendly features, and robust construction, it offers an exceptional choice for businesses seeking to serve high-quality coffee efficiently.