Contents
JDF-4D, JDF-4SB
Phone 217 529-6601 FAX 217
BUNN-O-MATIC Commercial Product Warranty
Introduction
Recommended Daily Cleaning Instructions
Required Regular Maintenance
Remedy
Problem Probable Cause
Cold Water Circulation
Dispenser Locked Out
Problem Probable Cause Remedy
Refrigeration
Ed replace relay
When dispensing. If yes, replace
Continuity
Check for kinked flex line
Concentrate only
Water only
Water pressure greater than
Nect fittings
Tray
100psi
Unit is not working
Pump tubing Inspect, clean, or replace tubing Age
Adapter assembly
Replace control board
Service
Component Access
Servicecont Access Panels
Access Panels
Servicecont Dispense Platform Removal
Dispense Platform Removal
Ballast JDF-2S,4S
Service
Test Procedure
Location
Remove the four screws attaching the fan and cover assembly
Cabinet Fan all Models
LG Compressor JDF-2S,4S,4D
Location
Compressor
Design Pressures High 335 Low 88 psi
GD Compressor JDF-2S,4S,4D
Compressor
Disconnect and remove the transformer
Compressor JDF-4SB
Compressor Thermal
BLU/BLK
Compressor Switch all Models
Compressor Switch
Condenser Fan all Models
Condenser FAN
Test Procedure Power Supply Circuitry
Control Board, Main all Models
Source. The indication must be 24 volts ac
Portion Control Board JDF-2S,4S
With a voltmeter, back probe check the voltage
To the transformer See Transformer
Push Button Control Board JDF-4D
Push Button Control Board
Portion Control Board JDF-4D
Circulation Pump all Models
With a voltmeter
Return power to the dispenser
Dispense Platform Switch all Models
Disconnect the two black wires from the switch
Dispense Pump all Models except JDF-4D
Dispense Pump
Reconnect the two wires to the motor as shown in Fig
Dispense Motor all Models
Dispense Valve all Models
Dispense Valve
Dispense Switches JDF-2S, JDF-4S
Dispense Switches
Cold Water Dispense Switch JDF-4S only
Cold Water Dispense Switch
Dispense Membrane Switch all Models
Location
Membrane Switch
EMI Filter all Models
EMI Filter
Lamps, Holders and Ballasts Early Models
Lamps & Holders
LED regulator board
Disconnect power from the dispenser
LED Lamps JDF-2S, JDF-4S
Rectifier JDF-2S, JDF-4S
Rectifier
Volts ac for 120 volt models Volts ac for 230 volt models
Refer to to reconnect the wires
Relay all Models
Resistor all 230V Models
Resistor
Solenoid Cold Water JDF-4S only
If voltage is present as described, proceed to #5
Solenoid Inlet all Models
120V 1.2 kΩ 230V 3.84 kΩ
32 F 31.2k 34k Ω
Temperature Probe all Models
Temp Resistance Voltage
77 F 8k 10.2k Ω
77 F 350 Ω
Temperature Sensor all Models
32 F 5k Ω
Transformer all Models
Transformer Terminals
Transformer Lited Doors JDF-2S, JDF-4S
Water Q28
Compressor Relay Q25
Water Q27
Water Q7
Diagram for JDF-2S LED Lited Doors
Schematic Wiring
Schematic Wiring Diagram JDF-4S
Schematic Wiring Diagram JDF
Schematic Wiring Diagram JDF-4D
Schematic Wiring Diagram JDF-4D
Electrical Schematic Diagram