SERVICE (CONT.)

LG Compressor (JDF-2S,4S,4D)

JDF-4S shown

Test Procedures:

Compressor Relay: Refer to FIG. 8

1.Disconnect the dispenser from the power source.

2.Remove compressor terminal cover retainer (1).

3.Connect a voltmeter across the white wire and the

blue/black wire. Connect the dispenser to the power source.

The indication must be:

FIG. 7 COMPRESSOR

Location:

P1684.40

(a)120 volts ac for two wire 120 volt models or

(b)230 volts ac for two wire 230 volt models.

5.Disconnect the dispenser from the power source. If voltage is present as described, proceed to the fol- lowing test procedures.

If voltage is not present as described, refer to the Con- tactor and check the contactor.

6.Disconnect the white wire from the compressor relay.

7.Remove relay from the compressor.

8.Check for continuity across the terminal and the pin socket on the rear of the relay.

If continuity is present as described, the compressor

The compressor is located at the top of the dispenser frame.

1 2 3

GRN Wire

P4298.20

FIG. 8 COMPRESSOR THERMAL

OVERLOAD PROTECTOR LOCATION

1.Compressor Terminal Cover

2.Compressor Relay

3.Thermal Overload Protector

start relay is operating properly.

If continuity is not present as described, replace relay.

Compressor:

1.Remove relay and yhermal overload protector.

2.Check for continuity across the bottom pin on the compressor and the left top pin on the compressor.

If continuity is present as described, the electrical part of the compressor is operating properly.

If continuity is not present as described, replace the compressor.

Thermal Overload Protector:

1. Check for continuity across the terminals on the thermal overload protector (3).

If continuity is present as described, the thermal over- load protector is operating properly.

If continuity is not present as described, replace the thermal overload protector.

17

49179

110613

 

Image 17
Contents Phone 217 529-6601 FAX 217 JDF-4D, JDF-4SBBUNN-O-MATIC Commercial Product Warranty Introduction Recommended Daily Cleaning Instructions Required Regular Maintenance Remedy Problem Probable CauseCold Water Circulation Dispenser Locked Out Problem Probable Cause RemedyRefrigeration Continuity When dispensing. If yes, replaceEd replace relay Check for kinked flex lineWater only Concentrate onlyTray Nect fittingsWater pressure greater than 100psiAdapter assembly Pump tubing Inspect, clean, or replace tubing AgeUnit is not working Replace control boardComponent Access ServiceAccess Panels Servicecont Access PanelsDispense Platform Removal Servicecont Dispense Platform RemovalTest Procedure ServiceBallast JDF-2S,4S LocationCabinet Fan all Models Remove the four screws attaching the fan and cover assemblyLocation LG Compressor JDF-2S,4S,4DDesign Pressures High 335 Low 88 psi CompressorCompressor GD Compressor JDF-2S,4S,4DDisconnect and remove the transformer Compressor Thermal Compressor JDF-4SBBLU/BLK Compressor Switch Compressor Switch all ModelsCondenser FAN Condenser Fan all ModelsControl Board, Main all Models Test Procedure Power Supply CircuitryWith a voltmeter, back probe check the voltage Portion Control Board JDF-2S,4SSource. The indication must be 24 volts ac To the transformer See TransformerPush Button Control Board Push Button Control Board JDF-4DPortion Control Board JDF-4D With a voltmeter Circulation Pump all ModelsReturn power to the dispenser Dispense Platform Switch all ModelsDisconnect the two black wires from the switch Dispense Pump Dispense Pump all Models except JDF-4DDispense Motor all Models Reconnect the two wires to the motor as shown in FigDispense Valve Dispense Valve all ModelsDispense Switches Dispense Switches JDF-2S, JDF-4SCold Water Dispense Switch Cold Water Dispense Switch JDF-4S onlyLocation Dispense Membrane Switch all ModelsMembrane Switch EMI Filter EMI Filter all ModelsLamps & Holders Lamps, Holders and Ballasts Early ModelsLED regulator board Disconnect power from the dispenserLED Lamps JDF-2S, JDF-4S Rectifier Rectifier JDF-2S, JDF-4SVolts ac for 120 volt models Volts ac for 230 volt models Refer to to reconnect the wiresRelay all Models Resistor Resistor all 230V ModelsIf voltage is present as described, proceed to #5 Solenoid Cold Water JDF-4S only120V 1.2 kΩ 230V 3.84 kΩ Solenoid Inlet all ModelsTemp Resistance Voltage Temperature Probe all Models32 F 31.2k 34k Ω 77 F 8k 10.2k Ω77 F 350 Ω Temperature Sensor all Models32 F 5k Ω Transformer Terminals Transformer all ModelsTransformer Lited Doors JDF-2S, JDF-4S Water Q27 Compressor Relay Q25Water Q28 Water Q7Diagram for JDF-2S LED Lited Doors Schematic Wiring Schematic Wiring Diagram JDF-4S Schematic Wiring Diagram JDF Schematic Wiring Diagram JDF-4D Schematic Wiring Diagram JDF-4D Electrical Schematic Diagram
Related manuals
Manual 28 pages 48.61 Kb Manual 28 pages 35.87 Kb Manual 31 pages 40.19 Kb

JDF-4D, JDF-4SB, JDF-4S specifications

The Bunn JDF-4S is a high-performance commercial coffee brewer designed to meet the needs of busy coffee shops, restaurants, and other establishments requiring a reliable and efficient coffee brewing solution. This versatile machine boasts an array of advanced features and technologies, making it a prominent choice among professionals in the coffee industry.

One of the most notable features of the Bunn JDF-4S is its ability to brew up to 4 gallons of coffee per hour, ensuring that establishments can keep pace with high-demand environments. This capacity makes it an ideal choice for venues that experience peak periods of coffee consumption, minimizing wait times for customers. The machine is designed with a multiple-brew option, allowing users to select various brew methods, which can cater to diverse customer preferences.

The JDF-4S incorporates Bunn’s patented brewing technology, which utilizes a precision-controlled process to ensure optimal flavor extraction. The brewed coffee is delivered at an ideal temperature, typically between 195°F and 205°F, promoting maximum taste and aroma. The machine also features a programmable digital controller that enables users to set specific brew times and adjust water temperature settings to achieve consistent results.

Another significant characteristic of the Bunn JDF-4S is its durability and ease of use. Constructed with high-quality materials, the machine is built to withstand the rigors of daily operation. The user-friendly interface features a simple touchpad design for easy navigation and programming. Additionally, the machine includes a built-in diagnostics program, helping users quickly identify and troubleshoot potential issues, thereby minimizing downtime.

The JDF-4S also offers flexible brewing options, including iced coffee brewing, enhancing its versatility. It is compatible with Bunn’s extensive range of coffee and tea dispensers, allowing businesses to expand their beverage offerings effortlessly. Furthermore, the unit features an easy-access water reservoir for quick refilling and reduced wait times during busy service periods.

In terms of maintenance, the Bunn JDF-4S is designed with user convenience in mind. The machine includes a rinse and clean cycle to ensure optimal hygiene and coffee quality. Integrated clean alerts guide users through the cleaning process, promoting regular upkeep and ensuring the longevity of the brewer.

In summary, the Bunn JDF-4S represents a cutting-edge solution for coffee brewing that prioritizes performance, versatility, and ease of use. With its advanced brewing technology, user-friendly features, and robust construction, it offers an exceptional choice for businesses seeking to serve high-quality coffee efficiently.