ELECTRICAL REQUIREMENTS

This grinder has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.

OPERATING CONTROLS

Off/On/Start Switch

OFF - (upper position) Switching to this position stops all operation of the grinder.

ON - (middle position) The switch will return to this position after a grind cycle has begun and will remain in this position after grinding has ceased.

START - (lower, momentary position) Pressing the switch to this position and releasing initiates a grind cycle.

Hopper Selector Switch

LEFT - Switching to this position allows beans to be ground from the left hopper.

RIGHT - Switching to this position allows beans to be ground from the right hopper.

P734

Dispense Timer - DG-2

The dispense timer controls the amount of beans that will be ground in a cycle. The timer can be adjusted to dispense a different amount from each hopper. The scale is from 0.1 to 60.0 seconds. Refer to the Adjustments section for timer setting chart. See page 7.

 

 

 

 

 

 

 

 

 

 

 

+/Increase - (left momentary push-button)

 

DISPENSE TIME (Seconds)

 

Pressing this button will increase the dispense interval on the timer while

 

 

 

I 0.0

 

 

 

the readout is displayed. The interval will change slowly for the first second’s

 

 

 

 

DISPLAY

 

indication, then speed-up for the next fifteen second’s indication, and increase

 

Increase

 

 

 

 

Decrease

 

 

+

 

 

 

 

 

 

 

 

 

very fast after that until it reaches the limit on the scale.

 

 

 

 

 

 

 

 

 

 

 

 

Readout will be displayed for 5 minutes.

 

 

 

Timer can only be adjusted

 

DISPLAY - (center momentary push-button)

 

while readout is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

Pressing this button will display the current timer readout. The timer can

 

HAZARDOUS VOLTAGE

 

 

only be adjusted while the readout is displayed. The indication on the display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

will last for five minutes.

 

 

UNPLUG GRINDER

 

 

–/Decrease- (right momentary push-button)

 

 

BEFORE REMOVING!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P595

Pressing this button will decrease the dispense interval on the timer while

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the readout is displayed. The interval will change slowly for the first second’s

indication, then speed-up for the next fifteen second’s indication, and increase very fast after that until it reaches the limit on the scale.

4

10854 030300

 

Image 4
Contents BUNNDG-2 Contents #05876.0000 User Notices#20545.0000 Off/On/Start Switch Hopper Selector SwitchDispense Timer DG-2 Electrical RequirementsDG-2 Initial SET-UP WDG-2 Initial SET-UPSpecial SET-UP for Flavored Coffee Beans 10854 Cleaning Coffee GrindingBurr Adjustment AdjustmentsTimer Adjustment DG-2 Coffee Weight/Timer Settings Troubleshooting Problem Probable Cause Grinder will not startProblem RemedyWDG-2 Digital Display Control Fault Codes Problem Service Component AccessService Motors BunnMotor Timer DG-2 Motor Circuit AssemblyReplace if excessively worn or damaged Disconnect grinder from the power source Weigh Control Board WDG-2 P930 10854 Fan FuseWeigh Control Assembly WDG-2 Funnel Rails Mounting Bracket Service Wiring Diagrams Schematic Wiring Diagram DG2 60 HZSchematic Wiring Diagram WDG2 Wiring Diagrams