Bunn WDG-2 manual Coffee Weight/Timer Settings

Page 10

Coffee Weight/Timer Settings

Approx. 4.0 seconds per ounce, Medium Roast, Drip Grind.

Approx. 5.5 seconds per ounce, Dark Roast, Drip Grind.

Time will vary depending on bean density & grind size.

Check samples by weight.

DIGITAL CONTROL DISPLAY ASSEMBLY FUNCTION LIST - WDG-2

FUNCTION NO.

FUNCTION

Place funnel with filter into rails, press (Func) button to advance to Function One.

1.When entering this function, load sensor is tared. To gain access to remaining functions, press (+) or (-) button once to enter password(0). Display will read

(0)now press (Func).

2.Set weight offset, right grinder. Press (+) or (-) to adjust if necessary. Press (Func).

3.Set weight offset, left grinder. Press (+) or (-) to adjust if necessary. Press (Func).

4.Enter calibration mode? If yes, press (+) display will read (1) then press (Func). If no, press (Func).

NOTE - Pressing (Func) will return to idle display.

5.Use present weight as tare for calibration? If yes, press (+). Display will read

(1)then press (Func). If no, press (Func).

6.To calibrate by grinding coffee, press (+) display will then read (1) then press (Func).

7.Enter desired calibration weight using (+) and (-) buttons. Then press start switch on grinder. Display changes to 0.00 and shows increasing weight as coffee is ground. When grinding stops and 7 has reappeared in left corner of the display. Push (Func) to advance to Function 8 before removing funnel.

8.Weigh sample grind and enter actual weight onto the display by pressing (+) or (-) if necessary. To abort and retain old calibration enter 0.00. Press (Func) when complete.

10.Enter new password. To keep same password press (Func), to change pass- word press (+) or (-), press function to enter new password and return to function 0, normal operation.

NOTE: Display shows "----" when taring. Do not disturb while this is shown.

NOTE: WDG2 Models can be converted from weight based settings to timed settings by pressing the (+) and (-) buttons for 10 seconds. Repeating the process will convert back to weight based settings.

RANGE

MIN. MAX.

0000 9999

0.009.99

0.009.99

0 = No 1 = Yes

0 = No 1 = Yes

1 = Grind

3.0016.00

0.0016.00

0000 9999

10

10854 030300

 

Image 10
Contents BUNNDG-2 Contents #05876.0000 User Notices#20545.0000 Dispense Timer DG-2 Off/On/Start SwitchHopper Selector Switch Electrical RequirementsDG-2 Initial SET-UP WDG-2 Initial SET-UPSpecial SET-UP for Flavored Coffee Beans 10854 Cleaning Coffee GrindingBurr Adjustment AdjustmentsTimer Adjustment DG-2 Coffee Weight/Timer Settings Troubleshooting Problem Probable Cause Grinder will not startProblem RemedyWDG-2 Digital Display Control Fault Codes Problem Service Component AccessService Motors BunnMotor Timer DG-2 Motor Circuit AssemblyReplace if excessively worn or damaged Disconnect grinder from the power source Weigh Control Board WDG-2 P930 10854 Fan FuseWeigh Control Assembly WDG-2 Funnel Rails Mounting Bracket Service Wiring Diagrams Schematic Wiring Diagram DG2 60 HZSchematic Wiring Diagram WDG2 Wiring Diagrams