Bunn CW-APS, CWT-TSR service manual Problem, Cwtf-Tsr

Page 11

TROUBLESHOOTING (cont.)

PROBLEM

Inconsistent beverage level in dis- penser

Consistently low beverage level in the dispenser (CWT-APS, CWTF- APS, CWT-TS, CWTF-TS, CWT- TSR & CWTF-TSR)

Spitting or excessive steaming

PROBABLE CAUSE

1.Strainer /flow control (.222 GPM) (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR &

CWTF-TSR

2.Syphon System

3.Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can initiate corrosive reactions result- ing in serious leaks.

4.Water Pressure (CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWTF-TSR)

1.Timer

2.Strainer/flow Control (.222 GPM)

1. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can initiate corrosive reactions result- ing in serious leaks.

REMEDY

(A)Direction of flow arrow must be pointing towards the brewer.

(B)Remove the strainer/flow con- trol and check for obstruction. Clear or replace.

The brewer must be level or slightly lower in front to syphon properly.

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

The water pressure to the brewer must be at least 20 psi (138 kPa).

Timer must activate solenoid for at least two minutes and fifteen seconds.

(A)Direction of flow arrow must be pointing towards brewer.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

Inspect tank assembly for exces- sive lime deposits. Delime as re- quired.

Page 11

10690 062300

 

Image 11
Contents CWT-TSR Introduction WarrantyUser Notices Models CW-APS & CWT-TS Electrical RequirementsPlumbing Requirements Electrical Hook-UpModels CWTF-APS, CWTF-TS CWTF-TSR Plumbing RequirementsEarly MO Dels W/OUT Fauc ET Third Type Models W/FAUCET8A.Models CWA-PS & CW-TS Initial SET-UP4A.Models CW-APS & CW-TS 6A.Models CW-APS & CW-TSOperating Controls Adjusting Brew VolumesON/OFF Switch Start Switch5A.Models CW-APS & CW-TS CleaningCoffee Brewing Must be open TroubleshootingProblem Probable Cause Remedy Brew cycle will not start CWT No waterTSR TroubleshootingProblem Probable Cause Remedy CWTF-TS, CWT-TSR &CWTFCWTF-TSR ProblemDispenser Spitting or excessive steaming Dripping from sprayheadBeverage overflows dispenser Control Thermostat Syphon System Lime Build-upCWTF-TS, CWT-TSR, CWTF-TSR CWT-APS, CWTF-APS, CWT-TSBrewer is making unusal noises Tank Heater Remove and clean lime off the tank heater. SeeCWT-TS, CWTF-TS, CWT-TSR CWTF-TSR Contents ServiceComponent Access Control Thermostat ServiceLimit Thermostat Service Control ThermostatON/OFF Switch Location Test Procedures Disconnect the brewer from the power sourceSolenoid Valve Start Switch Terminals Start SwitchTank Heater Tank HeaterService Tank Heater Tank Heater Switch Tank Heater SwitchTank Heater Switch Terminals Service Tank Heater SwitchDisconnect the black and white wires to the sole- noid Service TIMEREarly ModelsOLD Style Service TimerIf voltage is as described, proceed to #7 Digital Brew Timer Late ModelsTimer Setting Service Digital Brew Timer Late Modelscont10690 10690 10690 10690 10690