Bunn CWT-TSR Troubleshooting, Problem Probable Cause Remedy, Cwtf-Ts, Cwt-Tsr &Cwtf, Bom

Page 10

TROUBLESHOOTING (cont.)

 

 

 

 

PROBLEM

PROBABLE CAUSE

 

REMEDY

Brew cycle will not start (cont.)

3. ON/OFF Switch

 

Refer to Service - ON/OFF Switch

(CWT-APS, CWTF-APS, CWT-TS,

 

 

 

for testing. See page 18

CWTF-TS, CWT-TSR &CWTF-

4. Start Switch

 

Refer to Service - Start Switch for

TSR)

 

 

 

 

 

testing procedures. See page 20

 

5. Timer

 

 

Refer to Service - Timer for testing

 

 

 

 

procedures. See page 25 or 27

 

6. Solenoid Valve

 

Refer to Service - Solenoid Valve

 

 

 

 

for testing procedures. See page

 

 

 

 

19

 

7. Water

strainer/flow

control

(A) Direction of flow arrow must

 

(.222 GPM)

 

be pointing towards brewer.

 

 

 

 

(B) Remove the strainer/flow con-

 

 

 

 

trol and check for obstructions.

 

 

 

 

Clear or replace.

Water is not hot

1. Tank Heater Switch

 

Refer to Service - Tank Heater

 

 

 

 

Switch for testing procedures. See

 

 

 

 

page 23

 

2. Limit Thermostat

 

Refer to Service - Limit Thermo-

 

CAUTION - Do not eliminate or

stat for testing procedures. See

 

bypass limit thermostat. Use only

page 17

 

BOM

replacement

part

 

 

#29329.1000

 

 

 

3. Control Thermostat

 

Refer to Service - Control Ther-

 

 

 

 

mostat for testing procedures. See

 

 

 

 

page 16

 

4. Tank Heater

 

Refer to Service - Tank Heater for

 

 

 

 

testing procedures. See page 21

Page 10

10690 062300

 

Image 10
Contents CWT-TSR Warranty IntroductionUser Notices Electrical Hook-Up Electrical RequirementsPlumbing Requirements Models CW-APS & CWT-TSThird Type Models W/FAUCET Plumbing RequirementsEarly MO Dels W/OUT Fauc ET Models CWTF-APS, CWTF-TS CWTF-TSR6A.Models CW-APS & CW-TS Initial SET-UP4A.Models CW-APS & CW-TS 8A.Models CWA-PS & CW-TSStart Switch Adjusting Brew VolumesON/OFF Switch Operating ControlsCoffee Brewing Cleaning5A.Models CW-APS & CW-TS Brew cycle will not start CWT No water TroubleshootingProblem Probable Cause Remedy Must be openCWTF-TS, CWT-TSR &CWTF TroubleshootingProblem Probable Cause Remedy TSRProblem CWTF-TSRControl Thermostat Syphon System Lime Build-up Spitting or excessive steaming Dripping from sprayheadBeverage overflows dispenser DispenserCWT-APS, CWTF-APS, CWT-TS CWTF-TS, CWT-TSR, CWTF-TSRCWT-TS, CWTF-TS, CWT-TSR CWTF-TSR Remove and clean lime off the tank heater. SeeBrewer is making unusal noises Tank Heater Component Access ServiceContents Service Control ThermostatService Control Thermostat Limit ThermostatON/OFF Switch Solenoid Valve Test Procedures Disconnect the brewer from the power sourceLocation Start Switch Start Switch TerminalsTank Heater Tank HeaterService Tank Heater Tank Heater Switch Tank Heater SwitchService Tank Heater Switch Tank Heater Switch TerminalsService TIMEREarly Models Disconnect the black and white wires to the sole- noidService Timer OLD StyleDigital Brew Timer Late Models If voltage is as described, proceed to #7Service Digital Brew Timer Late Modelscont Timer Setting10690 10690 10690 10690 10690