Bunn CWT-TS Solenoid Valve, Location, Test Procedures Disconnect the brewer from the power source

Page 19

SERVICE (cont.)

SOLENOID VALVE

If continuity is not present as described, replace the

solenoid valve.

P1127.40

FIG. 8 SOLENOID VALVE

Location:

The solenoid valve is located inside the trunk on the center lower part of the component bracket.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Disconnect the white and black wires from the solenoid valve. With the "ON/OFF" switch in the "ON" (upper) position press the start switch.

3.With a voltmeter, check the voltage across the white and black wires. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.

b)200 to 240 volts ac for two wire 200 or 240 volt models.

c)100 volts ac for two wire 100 volt models.

4.Disconnect the brewer from the power source,

If voltage is present as described, proceed to #5

If voltage is not present as described, refer to Wiring Diagrams and check brewer wiring harness.

5.Check for continuity across the solenoid valve coil terminals.

If continuity is present as described, reconnect the white and black wire from the timer.

6.Check the solenoid valve for coil action. Connect the brewer to the power source. With "ON/OFF" switch in the "ON" (upper) position press start switch and listen carefully in the vicinity of the solenoid valve for a" clicking" sound as the coil magnet attracts.

7.Disconnect the brewer from the power source.

If the sound is heard as described and water will not pass through the solenoid valve, there may be a blockage in the water line before the solenoid valve, or the solenoid valve may require inspection for wear and removal of waterborne particles.

If the sound is not heard as described, replace the solenoid valve.

Removal and Replacement:

1.Remove the white and black wires from the sole- noid valve.

2.Turn off the water supply to the brewer.

3.Disconnect the water lines to and from the sole- noid valve.

4.Remove the two #8-32 screws securing the sole- noid mounting bracket to the component bracket. Remove solenoid bracket and solenoid valve as an assembly.

5.Remove the two #10-32 screws and lockwashers securing the solenoid valve to the solenoid bracket.

6.Using two #10-32 screws and lockwashers install new solenoid valve on solenoid mounting bracket.

7.Using two #8-32 screws install solenoid valve and bracket to the component bracket.

8.Securely fasten the water lines to and from the solenoid valve.

9.Refer to Fig. 9 when reconnecting the wires.

WHI from Timer

BLK from Timer

P1132.50

FIG. 9 SOLENOID VALVE TERMINALS

Page 19

10690 062300

 

Image 19
Contents CWT-TSR Introduction WarrantyUser Notices Models CW-APS & CWT-TS Electrical RequirementsPlumbing Requirements Electrical Hook-UpModels CWTF-APS, CWTF-TS CWTF-TSR Plumbing RequirementsEarly MO Dels W/OUT Fauc ET Third Type Models W/FAUCET8A.Models CWA-PS & CW-TS Initial SET-UP4A.Models CW-APS & CW-TS 6A.Models CW-APS & CW-TSOperating Controls Adjusting Brew VolumesON/OFF Switch Start SwitchCoffee Brewing Cleaning5A.Models CW-APS & CW-TS Must be open TroubleshootingProblem Probable Cause Remedy Brew cycle will not start CWT No waterTSR TroubleshootingProblem Probable Cause Remedy CWTF-TS, CWT-TSR &CWTFCWTF-TSR ProblemDispenser Spitting or excessive steaming Dripping from sprayheadBeverage overflows dispenser Control Thermostat Syphon System Lime Build-upCWTF-TS, CWT-TSR, CWTF-TSR CWT-APS, CWTF-APS, CWT-TSCWT-TS, CWTF-TS, CWT-TSR CWTF-TSR Remove and clean lime off the tank heater. SeeBrewer is making unusal noises Tank Heater Component Access ServiceContents Control Thermostat ServiceLimit Thermostat Service Control ThermostatON/OFF Switch Solenoid Valve Test Procedures Disconnect the brewer from the power sourceLocation Start Switch Terminals Start SwitchTank Heater Tank HeaterService Tank Heater Tank Heater Switch Tank Heater SwitchTank Heater Switch Terminals Service Tank Heater SwitchDisconnect the black and white wires to the sole- noid Service TIMEREarly ModelsOLD Style Service TimerIf voltage is as described, proceed to #7 Digital Brew Timer Late ModelsTimer Setting Service Digital Brew Timer Late Modelscont10690 10690 10690 10690 10690