SERVICE (cont.)
TIMER (cont.)
If voltage is present as described, the brew timer is operating properly. Reset the timer dial as required, to obtain the desired brew volume.
If voltage is not present as described, replace the timer.
Removal and Replacement:
1.Separate all connectors between the brewer wir- ing harness and the timer.
2.Remove the one
component bracket.
3Install new timer circuit board as described in Late
Model Timer section on the following pages.
4.Refer to Fig. 19 when reconnecting the wires.
5.Install the Timer Setting decal, provided with the replacement timer kit, below the schematic on the inside of the front access panel.
6.Adjust the timer as required. Refer to Late Model Timer section on the following pages.
To Main Wiring Harness
WHI to Solenoid Valve |
|
BLK to Solenoid Valve |
|
OLD STYLE | P1136 |
FIG. 17 TIMER TERMINALS
Page 26 | 10690 062300 |
|