SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)(cont.)

Timer Setting:

NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed.

1.Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the “SET” position on the circuit board.

To increase a brew volume, place the ON/OFF switch in the “ON” position, press and hold the START switch until three clicks are heard. Release the switch and press it again one or more times. (Failure to re- lease the switch within two seconds after the third click causes the volume setting to be aborted and pre- vious volume setting will remain in memory.) Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.

To decrease a brew volume, place the ON/OFF switch in the “ON” position, press and release the START switch once for every two-second interval to be removed from the total brew time period; then im- mediately press and hold down the START switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and pre- vious volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the de- sired volume has been achieved.

2.Setting brew volumes. To set a brew volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. Place the ON/OFF switch in the “ON” position, press and hold the START switch until three distinct clicks are heard and then release the switch. (Failure to release the switch within two seconds after the third click causes the volume set- ting to be aborted and previous volume setting will remain in memory.)

View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF”.

NOTE: Several ounces of water will continue to sy- phon from the tank after turning the switch “OFF”. The brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.

NOTE: When brewing coffee, volume will decrease due to absorption by the coffee grounds.

3.Setting programming disable feature. If it be- comes necessary to prevent anyone from changing brew time once programmed, you can set the SET/ LOCK switch to the “LOCK” position. This will pre- vent any further programming until switch is once again put into the “SET” position.

BLU/BLK wire from TL5 to P1

 

WHI/GRN wire from TL4 to (WHI) Solenoid

 

WHI/BLU wire from TL3 to (BLK) Solenoid

 

WHI wire from TL2 to P2

 

BLK wire from TL1 to P3

P2037

FIG. 19 DIGITAL TIMER WIRING

Page 28

10690 062300

Image 28
Contents CWT-TSR Warranty IntroductionUser Notices Electrical Requirements Plumbing RequirementsElectrical Hook-Up Models CW-APS & CWT-TSPlumbing Requirements Early MO Dels W/OUT Fauc ETThird Type Models W/FAUCET Models CWTF-APS, CWTF-TS CWTF-TSRInitial SET-UP 4A.Models CW-APS & CW-TS6A.Models CW-APS & CW-TS 8A.Models CWA-PS & CW-TSAdjusting Brew Volumes ON/OFF SwitchStart Switch Operating ControlsCoffee Brewing Cleaning5A.Models CW-APS & CW-TS Troubleshooting Problem Probable Cause RemedyBrew cycle will not start CWT No water Must be openTroubleshooting Problem Probable Cause RemedyCWTF-TS, CWT-TSR &CWTF TSRProblem CWTF-TSRSpitting or excessive steaming Dripping from sprayhead Beverage overflows dispenserControl Thermostat Syphon System Lime Build-up DispenserCWT-APS, CWTF-APS, CWT-TS CWTF-TS, CWT-TSR, CWTF-TSRCWT-TS, CWTF-TS, CWT-TSR CWTF-TSR Remove and clean lime off the tank heater. SeeBrewer is making unusal noises Tank Heater Component Access ServiceContents Service Control ThermostatService Control Thermostat Limit ThermostatON/OFF Switch Solenoid Valve Test Procedures Disconnect the brewer from the power sourceLocation Start Switch Start Switch TerminalsTank Heater Tank HeaterService Tank Heater Tank Heater Switch Tank Heater SwitchService Tank Heater Switch Tank Heater Switch TerminalsService TIMEREarly Models Disconnect the black and white wires to the sole- noidService Timer OLD StyleDigital Brew Timer Late Models If voltage is as described, proceed to #7Service Digital Brew Timer Late Modelscont Timer Setting10690 10690 10690 10690 10690