SERVICE (cont.)
CONTROL THERMOSTAT (cont.)
source. The indication must be:
a)120 volts ac for two wire 120 volt models.
b)200 to 230 volts ac for two wire 200 volt or 230 volt models.
8.Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5" above the bulb, the control thermostat is operating properly.
If voltage is not present as described, replace the thermostat.
Removal and Replacement:
1.Disconnect the control thermostat wires.
2.Remove the thermostat capillary bulb by firmly
3.Remove the one
4.Slide the grommet to the line 4.5" above the bulb on the new capillary tube.
5.Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid.
6.Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical posi- tion.
NOTE - The capillary tube must be clear of any electri- cal termination and not kinked.
7.Using one
8.Adjust the control thermostat as required.
FIG. 11-1 CONTROL THERMOSTAT TERMINALS
FIG. 11-2 REPLACEMENT CONTROL THERMOSTAT
Page 11 | 41722 070209 |
|