Bunn 41722.0000A manual Dry coffee grounds remain, Funnel Brewer is making unusal noises

Page 8

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

Weak beverage

1. Filter Type

 

2.

Coffee Grind

 

3.

Sprayhead

 

4.

Funnel Loading

 

5.

Water Temperature

Dry coffee grounds remain in the

1. Funnel Loading

funnel

 

Brewer is making unusal noises

1. Solenoid

2. Plumbing Lines

3. Water Supply

Page 8

REMEDY

BUNN® paper filters must be used for proper extraction.

A fine or drip grind must be used for proper extraction.

A six-hole stainless steel spray- head must be used for proper extraction.

The BUNN® paper filter must be centered in the funnel and the bed of ground leveled by gentle shaking.

Place an empty funnel on an empty dispenser beneath the sprayhead. Initiate a brew cycle and check the water temperature immediately below the sprayhead with a ther- mometer. The reading should not be less than 200°F (93°C). Adjust the control thermostat to increase the water temperature. Replace if necessary.

The BUNN® paper filter must be centered in the funnel and the bed of grounds leveled by gently shaking.

The nut on the solenoid must be tight or it will vibrate during operation.

Plumbing lines should not resting on the counter top.

(A)The brewer must be connected to a cold water line.

(B)Water pressure to the brewer must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi (345 kPa).

41722 070209

Image 8
Contents TB3/TB6 Series Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents To the brewer Probable Cause RemedyBrew cycle will not start No water Problem Brew cycle will not start Water is not hotProbable Cause Control Thermostat Tank HeaterInconsistent beverage level Surfaces can initiate corrosiveReactions resulting in serious LeaksBeverage overflows dispenser Refer to Service Timer for test- ing proceduresSpitting or excessive steaming Dripping from sprayhead Plumbing Lines Water Supply Dry coffee grounds remainFunnel Brewer is making unusal noises Cont Tank heater Problem Probable Cause RemedyBrewer is making unusal noises Tank Heater Location Control thermostat is located in the hood Component AccessControl Thermostat Disconnect the control thermostat wires Adjust the control thermostat as requiredRemove all wires from limit thermostat termi- nals Limit Thermostat1680W-120V 1680W-100V 1680W-230V 29.0 33.7 Disconnect the brewer from the power supplyTank Heater Orange light Lighted ON/OFF Switch TB3/TB3QRefer to -2 when reconnecting the wires Switch is located on the front control panel Through four when the switch is in the oposite PositionSwitch If continuity is present as described, replace the wiresStart Switches 37080.0001to T. StatInlet Valves BREW/DILUTION Timer TB3 & TB6 BREW/DILUTION Timer Triacs Triacs TH-1/MV-1 Brew solenoid TH-2/MV-2 Dilution solenoidWhite Red Neutral L2 Digital Brew Timer TB3Q & TB6QTerminals ½ batch connector Digital Timer Triacs Triacs MV-2 Brew solenoid output MV-1 LineSchematic Wiring Diagram TB3Q Volts AC Wire Single PhaseSchematic Wiring Diagram TB3, TB3B, TB3-LP Schematic Wiring Diagram TB3Q Schematic Wiring Diagram TB3Q W/SWEETENER & Empty BAG Detect Schematic Wiring Diagram TB6 Schematic Wiring Diagram TB6Q