TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
Water is not hot
PROBABLE CAUSE
3.ON/OFF Switch
4.Start Switch
5.Timer
6.Solenoid Valve
7.Water strainer/flow control (If equipped)
1.(A) Limit Thermostat
(B)Thermal
2.Control Thermostat
3.Tank Heater
REMEDY
Refer to Service - ON/OFF Switch for testing.
Refer to Service - Start Switch for testing procedures.
Refer to Service - Timer for test- ing procedures.
Refer to Service - Solenoid Valve for testing procedures.
(A)Direction of flow arrow must be pointing towards brewer.
(B)Remove the strainer/flow control and check for obstruc- tions. Clear or replace.
Refer to Service - Limit Ther- mostat for testing procedures. Thermal
Refer to Service - Control Ther- mostat for testing procedures.
Refer to Service - Tank Heater for testing procedures.
Page 5 | 41722 070209 |
|