Bunn 41722.0000A manual Lighted ON/OFF Switch TB3/TB3Q, Orange light

Page 14

SERVICE (cont.)

LIGHTED ON/OFF SWITCH (TB3/TB3Q)

P/N 37080.0000

Orange light

FIG. 14-1 LIGHTED ON/OFF SWITCH

Location:

The ON/OFF switch is located in the front of the hood, above and to the left of the brew funnel.

Test Procedure:

Brewers W/Out Half Batch or Sweetener Options

1.Disconnect the brewer from the power source.

2.Remove the wires from all four terminals.

3.Check for continuity across the two terminals on the lower right of the switch (as shown). Continuity must be present across these terminals in the ON position.

If continuity is present as described, reconnect the wires, the switch is operating properly. If continuity is not present as described, replace the switch.

NOTE: No continuity will show across the upper left terminals of the lighted switch since the light is neon.

Removal and Replacement:

1.Remove the wires from the switch terminals.

2.Compress the clips inside the hood and gently push the switch through the opening.

3.Push the new switch into the opening and spread the clips to hold the switch captive in the hood.

4.Refer to FIG. 14-2 when reconnecting the wires.

BLACK

WHITE

WHT/VIO

P/N 37080.0000

2 WHT/VIO

FIG. 14-2 LIGHTED ON/OFF SWITCH TERMINALS

Page 14

41722 070209

 

Image 14
Contents TB3/TB6 Series Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Contents To the brewer Probable Cause RemedyBrew cycle will not start No water Probable Cause ProblemBrew cycle will not start Water is not hot Control Thermostat Tank HeaterReactions resulting in serious Inconsistent beverage levelSurfaces can initiate corrosive LeaksBeverage overflows dispenser Refer to Service Timer for test- ing proceduresSpitting or excessive steaming Dripping from sprayhead Plumbing Lines Water Supply Dry coffee grounds remainFunnel Brewer is making unusal noises Cont Tank heater Problem Probable Cause RemedyBrewer is making unusal noises Tank Heater Location Control thermostat is located in the hood Component AccessControl Thermostat Disconnect the control thermostat wires Adjust the control thermostat as requiredRemove all wires from limit thermostat termi- nals Limit Thermostat1680W-120V 1680W-100V 1680W-230V 29.0 33.7 Disconnect the brewer from the power supplyTank Heater Orange light Lighted ON/OFF Switch TB3/TB3QRefer to -2 when reconnecting the wires Switch Switch is located on the front control panelThrough four when the switch is in the oposite Position If continuity is present as described, replace the wiresStart Switches 37080.0001to T. StatInlet Valves BREW/DILUTION Timer TB3 & TB6 BREW/DILUTION Timer Triacs Triacs TH-1/MV-1 Brew solenoid TH-2/MV-2 Dilution solenoidWhite Red Neutral L2 Digital Brew Timer TB3Q & TB6QTerminals ½ batch connector Digital Timer Triacs Triacs MV-2 Brew solenoid output MV-1 LineSchematic Wiring Diagram TB3Q Volts AC Wire Single PhaseSchematic Wiring Diagram TB3, TB3B, TB3-LP Schematic Wiring Diagram TB3Q Schematic Wiring Diagram TB3Q W/SWEETENER & Empty BAG Detect Schematic Wiring Diagram TB6 Schematic Wiring Diagram TB6Q