SERVICE (cont.)
LIMIT THERMOSTAT
FIG. 12-1 LIMIT THERMOSTAT
Location:
The limit thermostat is located inside the rear of the hood on the tank lid.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the blue and black wires from the limit thermostat.
3.Check for continuity across the limit thermostat terminals with a ohmmeter.
If continuity is present as described, the limit thermostat is operating properly.
If continuity is not present as described, replace the limit thermostat.
Removal and Replacement:
1.Remove all wires from limit thermostat termi- nals.
2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat.
3.Carefully slide the new limit thermostat into the retaining clip.
4.Refer to the schematics when reconnecting the wires.
to Tank |
|
|
| Lead from |
|
|
| ||
Heater Switch |
| Control Thermostat | ||
|
|
|
|
|
|
|
|
|
|
FIG. 12-2 LIMIT THERMOSTAT TERMINALS