PROGRAMMING - SMART WAVE WITH DISPLAY
BREW VOLUME SET-UP:
NOTE: Maximum water on time is 5 minutes.
1.Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A" brew switch. The display will then change to
2.Press and release "HIDDEN" switch until display reads A2. This represents the adjust mode "Brew Meter" (Pulse Brew) for the "A" brew switch. The display will then change to
3.Press and release "HIDDEN" switch until display reads A3. This represents the adjust mode "Drip Out Time" for the "A" brew switch. The display will then change to
4.Repeat steps 1
| Adjustment | Default | Min. | Max. | Increments |
A1 | = Brew switch "A" Brew time | 2:05 | 0:26 | 5:00 | 1 second |
A2 | = Brew switch "A" Brew meter | 1 | 1 | 14 | 1 |
A3 | = Brew switch "A" Drip out time | 1:00 | 0:05 | 5:00 | 5 seconds |
B1 | = Brew switch "B" Brew time | 2:05 | 0:26 | 5:00 | 1 second |
B2 | = Brew switch "B" Brew meter | 1 | 1 | 14 | 1 |
B3 | = Brew switch "B" Drip out time | 1:00 | 0:05 | 5:00 | 5 seconds |
ADVANCED SET-UP:
Press the "HIDDEN" switch until display reads P1. This represents the advanced adjust modes .
| Adjustment | Default | Min. | Max. | Increments | |
P1 | = Temperature set | 200°F | 185°F | 205°F | 1 | Degree |
P2 | = Ready Temperature | 195°F | 180°F | 198°F | 1 | Degree |
P3 | = Brew Count (Display Only) | 0 | 0 | 9999 | 1 | Brew Cycle |
P4 | = °F or °C | °F | N/A | N/A | N/A |
TECHNICIAN SET-UP:
Press the "HIDDEN" switch until display reads U1. This represents the Technician adjust modes .
| Adjustment | Default | Min. | Max. | Increments |
U1 | = Display Water Level Threshhold | < 10 | 0 | 255 | 1 |
U2 | = Adjust Water Level Threshhold | 85 | 30 | 220 | 1 |
U3 | - U7 FACTORY ADJUSTMENTS |
| DO NOT | ADJUST |
|
U8 | = Calibrate Temperature Sensor | 200°F | 190°F | 210°F | 1° |
Restore Factory Defaults:
Press the "ENABLE BREW ON/OFF" switch while applying AC power. Continue pressing the "ENABLE BREW ON/ OFF" switch for 10 seconds. During that 10 seconds the middle bars on the display will be on. After 10 Seconds the the 3 upper, middle and lower bars on the display will be lit for 5 seconds. During that 5 seconds, release and again press the "ENABLE BREW ON/OFF" switch to restore default settings – the display will show “DONE”.
Note: The Restore process cannot be done when Dip Switch # 1 is On (Program Lockout).
Page 11 | 40410 | 092211 |
|