Bunn 39338.0001 manual Operating Controls Portion Control only, Adjusting Dispense Volumes, Button

Page 8

OPERATING CONTROLS - PORTION CONTROL ONLY

(a) VOLUME SELECTOR BUTTONS

 

Press and release the button corre-

c.

sponding to the Small, Medium, or

 

Large volume, to select the desired

 

amount of water to be dispensed.

 

Pressing a different button after a

 

cycle has been initiated does not

 

change the volume in progress.

 

(b) AUTO STOP/MANUAL DISPENSE

 

BUTTON

 

Press and release button to stop a

 

dispense cycle. Press and hold button

 

to dispense manually.

(c) HIDDEN PROGRAMMING BUTTON a.

(d)LED INDICATORS

(e)DISPENSE NOZZLE

e.

ADJUSTING DISPENSE VOLUMES

NOTE: The dispenser should be at operating temperature before setting dispense volumes.

d.

b.

1.Press and hold the hidden programming button (c) located under the ® next to the BUNN logo on the front of the dispenser until the 3 LED's begin flashing from the left to the right. Release the button.

2.Place an empty graduated container under the dispense nozzle (e).

3.Press and release the batch size to be set (a). The LED's will stop flashing, and the LED over the button just pressed will come on steady. Water will begin to dispense into the container.

4.When the desired amount of water is dispensed, press and release the same button (a). The water will stop dispensing and the batch size is now set.

5.The LED's will begin flashing from left to right again. Repeat steps 2 thru 4 to set up the other batch sizes.

6.To exit the programming set up at any time, press and release the hidden button once (c). The dispenser is now ready for use.

8

46819 043012

 

Image 8
Contents Hot Water BUNN-O-MATIC Commercial Product Warranty Contents IntroductionUser Notices ALL Components areDual Volt Toggle Switch Electrical RequirementsCE Requirements Electrical Hook-UpPlumbing Requirements ALL Except OHW Plumbing Hook-UpInitial SET-UP H5M Initial SET-UP HW2Initial SET-UP OHW Normal USEAdjusting Dispense Volumes Volume Selector ButtonsHidden Programming Button a LED Indicators Dispense Nozzle Operating Controls Portion Control onlyProgramming H5-E, H5-PC, H5X, H10X Level 1 ProgrammingModel Displays P1 Left Center Right Button Button ButtonH2 F or C Selection H3 Restoring Factory DefaultsLevel 2 Programming Adjusting temperature Program lockout switchManual Energy Saver Mode Programming H5-ELEMENTH5H Programming H5-ELEMENT Cleaning Wall Mounted Installation 5 Gallon Models onlyDraining the Dispenser OHW Draining the Dispenser ALL 2, 5 & 10 Gallon Models