Henny Penny PFE-590, PFE-592 The display reads “HI” if the shortening temperature is 40 F above

Models: PFE-590 PFE-592

1 52
Download 52 pages 9.73 Kb
Page 25
Image 25
The display reads “HI” if the shortening temperature is 40° F above

 

Model PFE- 590/592

3-4. SWITCHES AND

 

INDICATORS (Continued)

 

HI Temperature Indicator

The display reads “HI” if the shortening temperature is 40° F above

 

the setpoint

Drop Indicator

The display reads “DROP” when the shortening has reached

 

the setpoint temperature (will read “DROP” 2° before setpoint and

 

4° above setpoint )

Done Indicator

The display reads “DONE” at the end of the Cook Cycle

Temperature Button

Allows the operator to read the temperature of the shortening while

 

in a Cook Cycle

SCAN Button

Allows the operator to toggle through any running multiple timers

FUNCTION Button

Used in the programming of the controls

EXIT FILL Button

After filtering the fryer, if in the Filter Lockout Mode, the display

 

reads “FILL” and the EXIT FILL button must be pressed

Multiple Timers

The control has the capability to run multiple timers; if more than

 

one product is being cooked, a timer can be started by pressing

 

more than one product button per Cook Cycle

 

The products must have the same setpoints, and the pressure

 

must be programmed off. See Programming Section.

703

3-6

Page 25
Image 25
Henny Penny PFE-590, PFE-592 manual The display reads “HI” if the shortening temperature is 40 F above