After the load compensation, press and release the

 

 

Model PFE- 590/592

3-14. PROGRAMMING

8.

After the load compensation, press and release the

(Continued)

 

FUNCTION button. “PROP” and “CONTROL” shows on

 

 

the left side of the display and the factory preset proportional

 

 

control temperature shows on the right side of the display.

 

9.

After the proportional control, press and release the

 

 

FUNCTION button. “ALM 1” and “TIME” flashes in

 

 

the left side of the display, and the first alarm time shows

 

 

on the right side of the display. To change the time the

 

 

alarm sounds, press the appropriate product buttons to set

 

 

the time. Ex: Press 1,0,0,0. 10:00 flashes on the right

 

 

side of the display, which means when the timer counts

 

 

down to 10 minutes, an alarm will sound.

 

10.

After alarm is set, press and release the FUNCTION

 

 

button. “ALM 1”, “SELF-’’, and “CANCEL” flashes

 

 

in the left side of the display and “YES” or “NO” shows

 

 

on the right side of the display. The yes and no can be

 

 

toggled by pressing any of the product buttons, (l -0).

 

 

“YES” means the alarm tone automatically stops after

 

 

several beeps. “NO” means someone must manually

 

 

press the appropriate product button to stop the alarm

 

 

tone.

 

11.

Repeat steps 9 and 10 for alarms 2 and 3.

 

12.

After alarm 3 is set, press and release the FUNCTION

 

 

button. “FILTER” and “CYCLES” shows on the left side

 

 

of the display and the filter cycle value is on the right side

of the display. The value is the number of Cook Cycles that must completed before the control signals the operator that the shortening needs filtered