Units being used outside the United States may not be shipped

 

Model PFE- 590/592

2-7. INTERNATIONAL

Units being used outside the United States may not be shipped

ELECTRICAL

with the power cord attached to the unit because of the different

REQUIREMENTS

wiring codes. The fryers are available from the factory wired for

 

208, 240, 380 and 415 volts, 3 phase, 50 Hertz service. A terminal

 

block is mounted inside the fryer for the cable wiring. Adecal on

 

the inside of the right side panel will help in the wiring of the unit.

 

CE units require a minimum wire size of 4mm to be wired to

 

the terminal block. If a flexible power cord is used, it must be

 

HO7RN type.

 

To install the power cord, follow these procedures:

 

1. Remove the right side panel of the unit.

 

2. Install the cord, with a strain relief, to the junction box.

 

3. Attach the wires to the terminal block according to the wiring

 

diagram on the side panel.

 

4. Pull the slack out of the cord and thread it down through the

 

the clamp on the frame, at the rear, left leg of fryer. Then run

 

the cable under the frame and out the rear of the fryer, so it

 

doesn’t interfere with the filter drain pan.

 

The filter drain pan must be as far back under fryer as

 

it will go, and the cover in place. Be sure the hole in the

 

cover lines up with the drain before opening the drain.

 

Failure to follow these instructions causes splashing of

 

shortening and could result in personal injury.

 

5. Wiring the fryer is now complete.