| Model PFE- 590/592 |
Units being used outside the United States may not be shipped | |
ELECTRICAL | with the power cord attached to the unit because of the different |
REQUIREMENTS | wiring codes. The fryers are available from the factory wired for |
| 208, 240, 380 and 415 volts, 3 phase, 50 Hertz service. A terminal |
| block is mounted inside the fryer for the cable wiring. Adecal on |
| the inside of the right side panel will help in the wiring of the unit. |
| CE units require a minimum wire size of 4mm to be wired to |
| the terminal block. If a flexible power cord is used, it must be |
| HO7RN type. |
| To install the power cord, follow these procedures: |
| 1. Remove the right side panel of the unit. |
| 2. Install the cord, with a strain relief, to the junction box. |
| 3. Attach the wires to the terminal block according to the wiring |
| diagram on the side panel. |
| 4. Pull the slack out of the cord and thread it down through the |
| the clamp on the frame, at the rear, left leg of fryer. Then run |
| the cable under the frame and out the rear of the fryer, so it |
| doesn’t interfere with the filter drain pan. |
| The filter drain pan must be as far back under fryer as |
| it will go, and the cover in place. Be sure the hole in the |
| cover lines up with the drain before opening the drain. |
| Failure to follow these instructions causes splashing of |
| shortening and could result in personal injury. |
| 5. Wiring the fryer is now complete. |
703 |