Henny Penny PFE-592, PFE-590 manual After the filter value is set, press and release the FUNCTION

Models: PFE-590 PFE-592

1 52
Download 52 pages 9.73 Kb
Page 40
Image 40
After the filter value is set, press and release the FUNCTION

 

 

Model PFE- 590/592

3-14. PROGRAMMING

13.

After the filter value is set, press and release the FUNCTION

(Continued)

 

button. “EOC” and “EXIT” flashes on the left side

 

 

of the display, and “COOL” shows on the right side of the

 

 

display. The end-of-cycle (EOC), exit point can be set to

 

 

COOL, SETP, or FLTR, by pressing any of the product

 

 

buttons (EOC). At the end of a Cook Cycle, the controls

 

 

can be set to return to: COOL, the setpoint temperature, or

 

 

to signal the operator to filter the shortening.

 

14.

After the end-of-cycle setpoint is set, press and release the

 

 

FUNCTION button. “HEAD” and “COUNT” flashes on

 

 

the left side of the display and a number shows on the

 

 

right side of the display. The number on the right, is the

 

 

number of head of chicken to be cooked when that product

 

 

button is pressed. The number can be changed by

 

 

pressing the appropriate product button.

 

 

Another product can be programmed while in the Program

 

 

Mode by following these procedures:

 

 

Press and hold the SCAN button at any time while in the

 

 

Program Mode, and the display scrolls “SELECT

 

 

PRODUCT”. Then press any of the product buttons,

 

 

(1-0), and now that product can be programmed.

 

15.

To program second interval, press and release the SCAN

 

 

button while in the Time Mode, of the first mode. “INT2”

 

 

and “TIME” flashes on the left side of the display. Then

 

 

follow the steps above, starting with step 4.

3-15. SPECIAL PROGRAM MODE

 

Review Usage

 

1.

Press and hold the FUNCTION button for two seconds until

 

 

“REG PROGRAM” shows in the display. As soon as

 

 

“REG PROGRAM” shows in the display, press and release

 

 

the FUNCTION button 1 time until “REVIEW USE” shows

 

 

in the display.

 

2.

“DAILY” shows in the display. Press any of the product

 

 

buttons to view the usage of that product. Press and hold the

 

 

FUNCTION button to exit Special Program Mode.

3-21

 

403

Page 40
Image 40
Henny Penny PFE-592, PFE-590 manual After the filter value is set, press and release the FUNCTION