Adjusting of the minimum of the top burners
Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of mini- mum.
The flame adjustment is done in the following way:
–Turn on the burner
–Tum the tap to the MINIMUM position
–Take off the knob
–With a small flat screwdriver turn the screw inside the tap rod to the correct regula- tion (fig. 39).
Normally for LPG, tighten up the regulation screw.
Fig. 39
41