CDA RC 9020 installation instructions Adjusting of the minimum of the top burners

Page 41

Adjusting of the minimum of the top burners

Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of mini- mum.

The flame adjustment is done in the following way:

Turn on the burner

Tum the tap to the MINIMUM position

Take off the knob

With a small flat screwdriver turn the screw inside the tap rod to the correct regula- tion (fig. 39).

Normally for LPG, tighten up the regulation screw.

Fig. 39

41

Image 41 Contents
Twin cavity Dual fuel cookers CDA Contents Assembling the backguard IntroductionGas burners Features and technical dataControl panel Controls description Control panelElectronic programmer main oven only Altering the audible signal Electronic timerElectronic clock fig Normal cooking without the use of the programmerAutomatic oven cooking Semi-automatic cooking Hob burners How to use the hob burnersElectric ignition Lighting of the hob burnersCorrect use of triple-ring burner Choice of burnerOperating principles How to use the Multifunction main ovenGeneral features Traditional convection cooking Oven lightHot air cooking GrillingDefrosting frozen foods Convection cooking with ventilation Ventilated grill cookingSimultaneous cooking of different foods SterilizationRegeneration Use of the grill Grilling and au gratinRoasting How to use the Conventional oven Traditional grilling Use of the rotisserie RotisserieDo’s and do not’s For your safetyDo’s and do not’s Important notes Cleaning the hob Care and maintenanceFlexible tube Gas tapsChanging the oven light Enamelled partsTriple ring burner BurnersStorage compartment Removal of the inner glass door panelAssembling and dismantling of the side runner frames Inside of ovenRemoving the oven door Door assemblyLocation For the Installer500 Fitting the adjustable feet Levelling the cooker Moving the cookerStability bracket Provison for ventilation Important Note Gas installationGas connection Installation to Natural GasLeft gas Right gas Inlet pipe Important Prescriptions for GAS Connection Conversion to Natural Gas or to LPG Injectors replacement of top burnersAdjusting of the minimum of the top burners Table for the choice of the injectors Lubrication of the gas tapsFor your safety please read the following information Electrical installationFeeder cable section type H05RRF Electrical feeder cable connectionAppliance servicing Limit of Cover GuaranteePage RC 9020 .. cookers