GE 960 Series manual Pressure Graphs, Psi

Page 22

Pressure Graphs

Injector #1031363

 

 

 

"A" in a 268 Valve

 

 

 

1.00

 

0.20

 

Total

 

 

 

 

 

 

0.75

 

0.15

 

Rinse

/hr

 

GPM

0.10

0.50

M

 

3

 

 

 

Brine Draw

0.050.25

0.000.00

20

40

60

80

100

120

 

 

 

PSI

 

 

400 600 800 1000 1200 1400 1600 1800 bar

Injector #1031365

"C" in a 268 Valve

1.75

 

0.20

Total

1.50

0.151.25

/hr

 

1.00

 

Rinse

 

 

 

0.10

GPM0.75

 

 

 

 

M

 

 

3

 

 

 

 

 

 

 

 

 

 

 

0.50

 

Brine Draw

 

0.05

 

 

 

 

 

 

 

 

 

 

0.25

0.000.00

20 40 60 80 100 120

PSI

400 600 800 1000 1200 1400 1600 1800 bar

M3/hr

M3/hr

0.30

0.25

 

1.25

 

 

0.20

 

1.00

 

 

0.15

GPM

0.75

 

 

 

0.10

0.50

 

0.050.25

0.000.00

0.30

2.25

0.252.00

1.75

0.201.50

 

1.25

0.15

GPM1.00

 

0.100.75

0.50

0.050.25

0.00 0.00

Injector #1031364

"B" in a 268 Valve

Total

Rinse

Brine Draw

20

40

60

80

100

120

 

 

 

 

 

 

 

 

 

PSI

 

 

 

 

 

 

400 600 800 1000 1200 1400 1600 1800 bar

Injector #1030272

"D" in a 268 Valve

Total

 

 

 

 

 

Rinse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brine Draw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

40

60

80

100

120

 

 

 

 

 

PSI

 

 

400 600 800 1000 1200 1400 1600 1800 bar

Backwash Number

7

8

9

10

12

13

14

Flow (GPM*)

1.2

1.6

2.0

2.5

3.9

4.1

4.8

Flow (LPM*)

4.5

6.0

7.6

9.5

14.76

15.5

18.2

 

 

 

 

 

 

 

 

*Approximate flow rates at 60 psi (414 kPa)

22

Image 22
Contents AutotrolPerforma ProSoft Table of Contents Water Line Connection InstallationLocation Selection Drain Line ConnectionRegenerant Line Connection Battery Back-UpOverflow Line Connection Placing Conditioner into Operation Electrical ConnectionLevel I Parameters Table ProSoft Control Conditioner SystemsProgramming Time of DaySalt Amount Time of RegenerationHardness CapacityRefill Control Value Level II Parameters TableSpecial Notes for Level II Parameters 75 Ft3 25 Ft3Level II Programming Parameters Parameter NameRegenerant Draw Value Manual RegenerationGuest Cycle Automatic Regeneration Performa 960 FA Control Cycle Filter System Performa 960 FA Level I Parameters TableFactor a Time of DayTime of Regeneration Regenerant DosageCapacity Settings for Various Size Iron Filters Performa 960 FA Level I Programming ParametersPerforma 960 FA Level II Programming Parameters Regenerant Draw Value Performa 960 FA Level II ParametersRefill Controller Slow Rinse TimeReserve Options RegenerationNormal Metered Water Usage Preventive Maintenance Removing the Valve Assembly for ServicingInjector Screen and Injector Water Meter Maintenance Removing the ControlDisconnect the turbine probe from the turbine assembly Specifications Pressure Graphs PSIService Position Flow DiagramsBackwash Position Brining/Slow Rinse Position Purge Position Regenerant Refill PositionReplacement Parts Performa ValveParts List Part Code Description QtyProSoft Control BypassValve Troubleshooting TroubleshootingProblem Possible Cause Solution Model 960 Alarms Control TroubleshootingAlarms Indication Description Cause SolutionRefer to the Manual Regeneration section Calcium Hypochlorite Disinfection of Water ConditionersSodium or Calcium Hypochlorite Application