GE 960 Series manual Flow Diagrams, Service Position, Backwash Position

Page 23

Identification of Control Valving

Valve Disc Principle of Operation

 

 

 

 

7 Backwash Drain Valves

5 Refill Valve

3 Inlet Valve

1 Regenerant Valve

6 Rinse Drain Valve

4 Outlet Valve

2 Bypass Valve

Flow Diagrams

1 Service Position

Hard Water

Soft Water

1

Inlet

3

2

5

2 Backwash Position

Hard Water

Soft Water

Brine

Adjustment

Inlet

2

3

5

1

Brine Adjustment

Outlet

Valve

4

6

7

Outlet

Valve

4

6

7

Backwash

Flow

Control

No.

Drain

No. Drain

1 - Closed

1 - Closed

2 - Closed

3 - Open

4 - Open

5 - Closed

6 - Closed

7 - Closed

2 - Open

3 - Closed

4 - Open

5 - Closed

6 - Closed

7 - Open

Mineral Tank

Brine Tank

Mineral Tank

Brine Tank

 

 

23

Image 23
Contents AutotrolPerforma ProSoft Table of Contents Drain Line Connection InstallationLocation Selection Water Line ConnectionOverflow Line Connection Battery Back-UpRegenerant Line Connection Electrical Connection Placing Conditioner into OperationTime of Day ProSoft Control Conditioner SystemsProgramming Level I Parameters TableCapacity Time of RegenerationHardness Salt Amount75 Ft3 25 Ft3 Level II Parameters TableSpecial Notes for Level II Parameters Refill Control ValueParameter Name Level II Programming ParametersGuest Cycle Manual RegenerationRegenerant Draw Value Automatic Regeneration Performa 960 FA Level I Parameters Table Performa 960 FA Control Cycle Filter SystemRegenerant Dosage Time of DayTime of Regeneration Factor aPerforma 960 FA Level I Programming Parameters Capacity Settings for Various Size Iron FiltersPerforma 960 FA Level II Programming Parameters Slow Rinse Time Performa 960 FA Level II ParametersRefill Controller Regenerant Draw ValueNormal Metered Water Usage RegenerationReserve Options Injector Screen and Injector Removing the Valve Assembly for ServicingPreventive Maintenance Removing the Control Water Meter MaintenanceDisconnect the turbine probe from the turbine assembly Specifications PSI Pressure GraphsBackwash Position Flow DiagramsService Position Regenerant Refill Position Brining/Slow Rinse Position Purge PositionPerforma Valve Replacement PartsPart Code Description Qty Parts ListBypass ProSoft ControlProblem Possible Cause Solution TroubleshootingValve Troubleshooting Indication Description Cause Solution Control TroubleshootingAlarms Model 960 AlarmsRefer to the Manual Regeneration section Application Disinfection of Water ConditionersSodium or Calcium Hypochlorite Calcium Hypochlorite