Anetsberger Brothers 14GS 14GU warranty Code Requirements

Page 5

CODE REQUIREMENTS

IMPORTANT: Read the Code Requirements and ALL installation instructions carefully, before starting the installation. Contact the factory if any problems or questions arise.

The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition); the Natural Gas Installation Code, CAN/ CGA-B149.1 (latest edition); or the Propane Gas Installation Code, CAN/CGA-B149.2 (latest edition), as applicable, including:

a.Disconnect the fryer and its individual shutoff valve from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of ½ psig (3.45 kPa).

b.Isolate the fryer from the gas supply piping system during any pressure testing of the gas supply system at test pressures equal to or less than ½ psig (3.45 kPa).

c.For fryers utilizing floor casters, the fryer instal- lation shall comprise a connector that complies with the Standard for Connectors for Mov- able Gas Appliances, ANSI Z21.69 (latest edition) or CAN/CGA 6.16 (latest edition), and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41 or CAN/CGA 1-6.9 (latest edition).

d.Restrict the movement of a caster-equipped fryer by using a limiting device (for example, a cable attached both to the fryer and to a fixture attached to the site structure) to avoid depend- ing on the connector and the quick-disconnect device or its associated piping to limit fryer movement.

e.Install this fryer on a non-combustible floor with its back and sides at least 6away from any combustible wall, as shown in Figure 2.

! WARNING

Install this fryer under a ventilation hood that conducts combustion pro- ducts outside the building. Venting must comply with ANSI/NFPA 96 (latest edition).

f.Install this fryer in a location where adequate combustion and ventilation air is available. Keep the area directly in front of the fryer open for adequate air flow to the burners. DO NOT obstruct the flow of combustion and ventilation air.

g.Keep the fryer area free and clear from combustibles and debris.

h.Attach a restraining device to each fryer, to prevent the unit from tipping, which could

cause splashing of hot liquid.

5

Image 5
Contents Anetsberger Brothers, Inc MX-14EG, MX-14EGUContents Models Covered By This Manual Shipping Container InspectionFryer Electrical Specifications Fryer GAS Supply SpecificationsCode Requirements Fryer Site Installation Requirements Installation RequirementsLEG Leveling Instructions Installation InstructionsLEG Installation Instructions Caster Leveling INSTRUC- Tions Caster Installation InstructionsCaster Leveling Instruc Fryer Restraining Device Installation InstructionsGAS Connection Instructions Fryer Operating Insructions Which will void the fryer warrantyFryer Preparation for USE Fryer Operating InstructionsGas Control Valve & Knob Positions Lighting ProcedureShutdown Procedure Food Product Daily Cleaning Procedure Monthly Maintenance Instructions Problem Cause Remedy Fryer Troubleshooting GuideFryer Troubleshooting Guide Problem Cause Main burners do not Thermostat has failed Recalibrated Limited Warranty Toll-free Customer & Warranty Service 800

14G, 14GS 14GU specifications

Anetsberger Brothers, a renowned name in the field of precision machining and manufacturing, has established its reputation with the introduction of the Anetsberger Brothers 14G, 14GS, and 14GU series. These machines are engineered to cater to diverse industrial needs, offering extensive capabilities in various applications such as metal working, fabrication, and assembly.

One of the main features of the Anetsberger Brothers 14G series is its robust construction, ensuring durability and longevity even in demanding environments. The machines are equipped with high-precision components that contribute to remarkable accuracy in machining operations. Users can expect tight tolerances and exceptional surface finishes, making them suitable for high-quality production standards.

The 14GS variant is enhanced with state-of-the-art technology that incorporates advanced control systems. With user-friendly interfaces, these systems allow operators to easily program and control machining processes, thereby increasing productivity. The integration of CNC (Computer Numerical Control) technology means that the 14GS can execute complex programming with precision, reducing the chances of human error and minimizing waste.

For industries that require versatility, the 14GU model stands out with its adaptability to various machining operations. This model is designed to handle an array of materials, including metals, plastics, and composites. The machine features interchangeable tooling options, making it ideal for businesses that engage in low to medium volume production runs. This flexibility ensures that companies can adjust their manufacturing processes based on changing demands without investing in additional machines.

All three models boast efficient energy consumption, contributing to reduced operational costs. Anetsberger Brothers has focused on sustainability, designing these machines not only for performance but also with eco-friendly practices in mind. Safety features have also been integrated to protect operators, ensuring a secure working environment.

In conclusion, the Anetsberger Brothers 14G, 14GS, and 14GU series offer exceptional performance characterized by durability, precision, and versatility. These machines are built for today’s fast-paced industrial demands, making them an asset for any manufacturing operation looking to enhance productivity and efficiency. By incorporating advanced technologies and user-centric design, Anetsberger Brothers continues to set benchmarks in the manufacturing industry.