FRYER TROUBLESHOOTING GUIDE (Continued)

PROBLEM

CAUSE

REMEDY

 

 

 

Liquid shortening does

1. Low gas supply pressure [less than 6

1. Measure the gas supply pres-

not reach the desired

W.C. for natural gas; (11W.C. for pro-

sure.

temperature for frying.

pane) when all other gas-powered equip-

Contact your local gas supplier

 

ment is operating], causing reduced heat

to obtain adequate gas supply

 

from main burners.

pressure.

 

2. Low gas manifold pressure [less than 3½

2. Measure the gas pressure at

 

W.C. for natural gas; (10W.C. for pro-

the fryer’s manifold pressure

 

pane).

tap. Adjust the manifold pres-

 

 

sure (see Figure 6), as neces-

 

 

sary: [a] Unscrew (and re-

 

 

tain) the threaded Main Burner

 

 

Regulator Adjustment Cover. [b]

 

 

Use a flat-blade screwdriver to

 

 

turn the regulator adjustment

 

 

screw (clockwise to increase;

 

 

counterclockwise to decrease)

 

 

to reset the pressure adjust-

 

 

ment. [c] Reinstall, and tighten,

 

 

the Regulator Adjustment

 

 

Cover, when finished.

 

3. Loosen knob on thermostat; or thermostat

3. Stir the shortening to mix the

 

requires calibration (temperature setting

hot shortening with some from

 

differs by about 10°F from measured

the lower ‘cool zone’ and allow

 

shortening temperature).

it to sit for 5 minutes. Turn the

 

 

thermostat knob until it ‘clicks’

 

 

on (causing the main burners to

 

 

flame); note the setting where

 

 

this occurs. Turn the thermo-

 

 

stat knob until it ‘clicks’ off

 

 

(causing the main burners to go

 

 

out); note the setting where this

 

 

occurs. Repeat this tempera-

 

 

ture ‘click points’ step at least

 

 

three times to ensure that

 

 

the shortening temperature has

 

 

stabilized.

 

 

Measure the temperature of

 

 

the shortening by inserting an

 

 

accurate thermometer about

 

 

4 inches into the shortening to

 

 

measure its temperature. If the

 

 

temperature difference between

 

 

the measured temperature and

 

 

the thermostat setting is 10°F

 

 

or less, the thermostat can be

 

 

recalibrated.

 

 

 

14

Image 14
Contents Fryer Contents Fryer GAS Supply Specifications Shipping Container InspectionFryer Electrical Specifications Code RequirementsInstallation Requirements LEG Leveling InstructionsGAS Connection Instructions Fryer Operating InstructionsFryer Operating Instructions Fryer Preparation for USELighting Procedure On setting with the valve markShutdown Procedure Daily Cleaning Procedure Fryer Troubleshooting Guide Monthly Maintenance InstructionsFryer Troubleshooting Guide Pilot Recalibrated Brated Limited Warranty