FRYER TROUBLESHOOTING GUIDE (Continued)
PROBLEM | CAUSE | REMEDY |
|
|
|
Liquid shortening does |
| Recalibrate the thermostat by: |
not reach the desired |
| (a) removing the cap on the |
temperature for frying. |
| thermostat control knob; (b) |
(Continued) |
| loosening the center brass hex |
|
| nut portion of the knob; (c) turn |
|
| the pointer portion of the knob to |
|
| the measured temperature value |
|
| of the thermostat setting. |
|
| Tighten the brass hex nut to lock |
|
| the adjustment. Replace the |
|
| cap on the knob. |
| 4. Thermostat setting is more than 20°F dif- | 4. Check the thermostat setting |
| ferent than measured shortening tempera- | against an accurate measure of |
| ture. | the shortening temperature. If |
|
| the temperature difference is |
|
| greater than 20°F, the thermo- |
|
| stat can possibly be recali- |
|
| brated. |
|
| Recalibrate the thermostat by: |
|
| (a) removing the cap on the |
|
| thermostat control knob; (b) |
|
| loosening the center brass hex |
|
| nut portion of the knob; (c) turn |
|
| the pointer portion of the knob |
|
| to the measured temperature. |
|
| Tighten the brass hex nut to lock |
|
| the adjustment. Replace the |
|
| cap on the knob. |
|
| If this calibration is unsuccess- |
|
| ful, the thermostat has failed and |
|
| must be replaced. |
|
|
|
15