Zenith 30009, 38291, 37691, 38201, 37671 Auxiliary Fan Attachment excluding HT boiling only models

Page 12

Auxiliary fan

connection

Cold water connection

Electrical

connections

Auxiliary Fan Attachment (excluding HT boiling only models)

The HydroTap is equipped with an auxiliary connection point for an exhaust fan on the rear panel close to the cold water inlet / flex and plug area. The fan kit is available as a spare part. The fan operates in parallel with the Condensor fan helping to remove heat from the cupboard space. This fan should be purchased and fitted to the HydroTap if the airfow characteristics of the cupboard space are inadequate for the effective removal of hot air thereby adversly affecting the operation of the HydroTap.

The fan can be installed so that it extracts air from, or forces air into the cupboard space, whichever is the most effective for your installation.

Application of the fan is of paramount importance in situations where the cupboard space reaches temperatures greater than 35ºC.

Boiling Water Safety Isolation (excluding HT boiling only models)

The HydroTap if equipped with a safety mode that allows protection against accidental operation by Infirmed or disabled persons.

1.On the LCD scroll through the menu to Hot Isolation.

2.Press adjust to activate.

3.Press the safety button on the tap head (3) three times rapidly. The LEDs will scroll from left to right (3) three times. This operation confirms the activation.

4.This isolates the boiling tap only. The LCD shows isolation mode is active.

5.To de-activate, press the safety button (3) three times rapidy.

The LED’s will scroll from right to left (3) three times. This operation confirms de-activation.

6.The LCD will show Normal Operation.

7.If de-activation mode is required, de-activate by scrolling through the menu and selecting de-activate when Hot Isolation Mode is displayed on the screen.

Page 12 of 20

Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005

Image 12
Contents Installation and Operating Instructions Zenith HydroTapContents Read These Warnings First Installation Requirements Models covered by these instructionsInstallation procedure Step a Installing the tap all modelsSpecial tools required Step B Installing the undersink unit all models Model B, BD and HT boiling only modelsStep D Connecting the water supply all models Filter Flush Mode filtered models onlyBoiling ChilledFont installation procedure Fixed to the Tap Head Assembly. These cannot be extendedOperating the Tap Cleaning Replacing the Filter filtered models onlyReset Litres Filtered Activating Sleep ModeActivating On / Off Mode Set DayAuxiliary Fan Attachment excluding HT boiling only models Trouble Shooting Symptom Possible Cause SolutionExploded View Chiller Module and Spare Parts Kit No DescriptionExploded View Boiler Module and Spare Parts Exploded View HT Series Boiling Only and Spare Parts KIT no DescriptionPage Page Page Warranty Information