BC 100 125
Model | Cups of | Glasses of | |
Boiling Water | Chilled Water | ||
| |||
| per Hour | per Hour |
Read These Warnings First continued
Frost Protection
If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings.
Installation Environment Considerations
This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet.
Models covered by these instructions
These Installation Instructions cover the entire Zenith HydroTap range. Use the chart on the left to identify the model you are using:
Commercial and Domestic Models:
BC | = Boiling and Chilled, Filtered, Timer |
BF | = Boiling, Filtered |
BD | = Boiling and Ambient Filtered |
B | = Boiling only (unfiltered) |
D | = Disabled Lever controls, (Optional order only) |
HT | = Domestic Models (boiling only are unfiltered, boiling/chilled are filtered) |
Boiling Water Capacity:
100 = 100 cups in one hour 150 = 150 cups in one hour
Chilled Water Capacity: (BC only)
125 = 125 glasses in one hour 175 = 175 glasses in one hour
Filtration: (BC, BD and BF only)
Note: The Cup measurement = 167mls, the Glass measurement = 200mls.
Installation Requirements
Before installing ensure that the following have been provided at the installation site:
•Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions. A table of dimensions is given below.
Model |
| Height |
| Depth |
| Width |
| Weight empty | Weight full | |||
|
|
|
| |||||||||
|
| mm (inch) |
| mm (inch) |
| mm (inch) |
| kg’s | lbs | kg’s lbs | ||
|
|
|
|
|
|
|
|
|
| |||
BC & HT 60/85 |
| 337 (13.2) |
| 430 (16.9) |
| 440 (17.3) |
| 28 | (61.7) | 34.5 (76) | ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||||
BC 100/125 |
| 337 (13.2) |
| 430 (16.9) | 440 (17.3) | 28 | (61.7) | 35 (77.1) | ||||
|
|
|
|
|
|
|
| |||||
BC 150/175 |
| 395 (15.5) |
| 465 (18.3) | 500 (19.6) | 29.5 | (65) | 38 (83.7) | ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||||
BD 60 |
| 353 (13.8) |
| 320 (12.5) | 290 (11.4) | 9 | (19.8) | 11.5 (25.3) | ||||
B 150 | 409 (16.1) | 340 (13.3) | 321 (12.6) | 10 |
| (22) | 14 | (30.8) | ||||
|
|
|
|
|
|
|
| |||||
B 100 |
| 353 (13.8) |
| 320 (12.5) | 290 (11.4) | 9.5 | (20.9) | 12 (26.4) | ||||
B 60 | 353 (13.8) | 320 (12.5) | 290 (11.4) | 9 | (19.8) | 11.5 | (25.3) | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: Add 65mm to the Depth to the
•A water supply connection with isolating valve inside the cupboard within reach of the 750 mm flexible connection and positioned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed.
•Power supply
Page 4 of 20 | Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 |