The power point must be located within reach of it’s cable. The appliance must be
positioned so that the plug is accessable.
Zip Hydrotap undersink assembly. The appliance must be placed in a horizontal position, as shown above.
Read These Warnings First
Safety
Do not allow young children, handicapped or infirm persons, to use the Zenith HydroTap without supervision.
Refrigerant
The Zenith HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the unit should be exposed to a naked flame. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration mechanic.
Qualifications
If any power cord or plug is damaged it must be repaired only by a qualified technician. To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson. The power cord and general power outlet must be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at the mouth of the tap. If the tap is not installed using the Font pedestal, ensure the tap body is located so the tap outlet safely drains into the sink bowl area.
NOTE: On startup, the controls take the system through a calibration process which causes the unit to
Lifting
Take care when lifting the Zenith HydroTap undersink unit. Some units may exceed safe lifting limits. Do not lift without assistance. The weights of the units are given in the table under the heading “Installation Requirements”. Do not lift the unit by the doors.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper air circulation must be provided. The system will operate satisfactorily only if the recommended air gaps are provided, these are 65mm min rear clearance and 50mm side clearance. An air vent is provided with each unit for high usage applications, this must be installed in the top half of the cupboard door as a matter of course. An optional fan kit is available and should be used to ensure adequate ventilation. Make sure that the ventilation grilles of the undersink unit are not obstructed.
Altitude (not HT boiling only series)
The Zenith HydroTap is equipped with a
Filter For models : BC, BD, BF
The Zenith HydroTap filter control is preset to 6000 Litres to provide
Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 | Page 3 of 20 |