Extron electronic MPA 152 PLUS manual Power Connector, MPA 152 Plus Panels and Cabling

Page 11
Figure 3. Power Connector

MPA 152 Plus

Ampli￿er

POWER 12V

0.7A MAX

PS 1220

Power Supply

DC Power Outputs

Power Receptacle

AC Power Cord

DC Power Cord

Captive Screw

Connector

Power Supply

Output Cord

DO NOT USE

Captive Screw

Connector

Tie

Wrap

Figure 3. Power Connector

ATTENTION:

Always use a power supply supplied by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product.

The amplifier is suitable for use in environmental air space in accordance with Section 300.22.C of the National Electrical Code, and Sections 2-128, 12‑010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.

Although the amplifier is plenum rated, the power supply provided with it is not. The power supply must not be placed in the plenum space. Cables to and from the amplifier must also be plenum rated. The DC power cord provided with the unit is not plenum rated.

The installation shall be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16.

The power supply shall not be permanently fixed to building structure or similar structure.

The length of the exposed wires in the stripping process is critical. The ideal length is 3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a short circuit between them. Any shorter and the wires can be easily pulled out even if tightly fastened by the captive screws.

NOTE: Do not tin the wires. Tinned wire does not hold its shape and can become loose over time.

MPA 152 Plus • Panels and Cabling

5

Image 11
Contents Audio MPA 152 PlusENERGY STAR Qualified Stereo Mini Power Amplifier User GuideSicherheitsanweisungen Deutsch Safety InstructionsSafety Instructions English Instructions de sécurité FrançaisRegulatory Compliance Guide on the Extron website FCC Class B NoticeNotifications Specifications AvailabilityConventions Used in this Guide Contents MPA 152 Plus Contents Introduction Important Safety InstructionsImportant Safety Instructions About the MPA 152 Plus MPA 152 Plus FeaturesMPA 152 Plus Introduction MPA 152 Plus FeaturesAbout the MPA 152 Plus MPA 152 Plus Introduction Panels and Cabling MPA 152 Plus Rear Panel FeaturesPower Connector MPA 152 Plus Panels and Cabling Figure 3. Power ConnectorAudio Inputs Figure 5. Remote Control Wiring Remote ControlWiring for remote control Ground to ground G Vol/Mute to C 10 V to Figure 7. MPA 152 Plus Summing Diagram Audio OutputFront Panel Features and Operation Setup and OperationFront Panel Features and Operation Setting Input LevelSetting Bass and Treble Remote Control OptionsDefeating the Auto Power-downTimer Amplifier Enters Standby Mode Too Early TroubleshootingAmplifier Fails to Exit Standby Mode PromptlyUL Guidelines for Rack Mounting MountingRack Mounting Back of the Rack Mounting Rack Mounting ProcedureOther Mounting Options Extron Warranty
Related manuals