Henny Penny OEA/OGA-342, OFE/OFG-342, OFE/OFG-341, OEA/OGA-341 Filter Switch Replacement

Page 22

Model OFE/OFG/OEA/OGA-341, 342

2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should

REPLACEMENT “open”, cutting off the pilot flame. This will prevent the fryer from heating while shortening is being drained from the frypot.

1.Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.The following check should be made to determine if the drain microswitch is defective.

a. Remove the two screws and nuts securing the microswitch

Figure 2-32to the drain rod valve bracket, and remove microswitch. Figure 2-32.

b.Remove wires from the switch. Figure 2-33.

c.Check for continuity across the two outside terminals of the drain switch. If the circuit is open, the drain switch is defective. The circuit opens by pressing on the actuator of the microswitch.

3.If defective, replace switch in reverse order.

Figure 2-33

2-14. FILTER SWITCH

 

REPLACEMENT

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Figure 2-34

2. Open the door (left door on 2 well units), and remove the 2

screws securing the switch box cover. Figure 2-34.

2-12

1003

Image 22
Contents Technical Manual Model OFE/OFG/OEA/OGA-341 FM06-030 Revised Table of Contents Which, if not avoided, could result in death or serious SafetyIntroduction InjuryProblem Cause Correction TroubleshootingIf maintenance procedures are not followed correctly Injuries and/or property damage could resultTroubleshooting Cleaning the fryer ThoroughlyTroubleshooting Problem Cause Correction Error Codes Display Cause Panel Board CorrectionError Codes Display Cause Panel Board Correction High Temperature Limit Control Maintenance HintsGas Units Remove the two screws securing the high limit to the bracket Remove the high limit from bracketPosition where it could accidentally touch the electrical Capillary line under and away from all electrical powerWires and terminals. The tube must never be in such a Power terminalsPower Switch Panel ReplacementComplete Control Power Switch Excess force will damage probe Temperature Probe Replacement Electric Flame SENSOR/ Pilot / Ignitor Assembly GASFlame SENSOR/ Pilot / Ignitor Assembly Gas Remove the control panel and heat shield from control area Boards Replacement ReplacementTransformer To avoid property damage, do not tamper with, or disassemble Filter Switch Replacement Filter Switch GAS Control Valve Remove screws securing the rear cover to the unit Blower Motor Replacement Blower Motor Replacement Heating Elements ElectricWire Nos Voltage Wattage Ohms cold Contactors Checkout Power RemovedHeating 30 31 34 35 36 FigureRe-apply power to unit and turn power switch to on Replacement Primary Contactor Heating Contactors ElectricSpeaker Assembly 106 Connect the two electrical wires High TemperatureLimit Control Electric Terminals. The tube must never be in such a position Line under and away from all electrical power wiresWhere it could accidentally touch the electrical power TerminalsMotor Removal Filter Pump and Motor Removal Transformer ReplacementAutolift Actuator Motor Replacement If applicableAutolift Actuator Motor Replacement Install new actuator in reverse order Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/C Drain switch wired N/O Drain switch wired N/O 707 Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O Drain switch wired N/O 106 Parts Information Introduction When OrderingWarranty Genuine PartsItem No Description Qty. per Well Gas Components Gas Burner Assembly Item No Description Qty. per Well Electric Components Item No Description Qty. per Well Item No Description Qty. per Well Model OFE/OFG/OEA/OGA-341 806 Item No Description Qty. per Unit √ recommended parts/*not shown √ recommended parts *not shown Item No Description Qty. per Well 2per well √ recommended parts/*not shown Item No Description Qty. per Well Item No Description Qty. per Well  recommended parts/*not shown OFG/OGA-341 OFG/OGA-342 Item No Description Qty. per Well OFG/OFE Electro Mechanical Parts List Part Number DescriptionItem No Description Qty ASSY. 341 Faucet DIRECT-CONNECT Parts List Before March 1 DIRECT-CONNECT Parts List Before March 1 Description QtyDescription Qty ROD Extension Filter Valve PIN-COTTER Fitting Connector Male 1209

OEA/OGA-341, OEA/OGA-342, OFE/OFG-341, OFE/OFG-342 specifications

Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 are advanced cooking equipment designed primarily for the foodservice industry. These models are part of Henny Penny’s renowned line of pressure fryers, which are celebrated for their ability to deliver consistently high-quality, crispy fried foods while maintaining efficiency and safety.

One of the standout features of these models is their patented pressure frying technology, which allows food to be cooked at higher temperatures and pressures compared to traditional frying methods. This not only reduces cooking time significantly but also helps seal in moisture and flavor, resulting in juicy, tender products with a superior texture. The pressure frying system also uses less oil, making it a more economical choice for busy kitchens.

The OFE/OFG-341 and OFE/OFG-342 models are designed for versatility and ease of use. They offer programmable controls that allow operators to customize cooking times and temperatures for a range of food items, from chicken and fish to vegetables. This adaptability ensures that cooks can achieve the desired results each time, regardless of the menu item. The digital display is user-friendly, allowing staff to navigate through settings with ease.

Safety and maintenance are paramount in these designs. Each model is equipped with a robust safety locking system to prevent accidental opening during the cooking process. Additionally, they feature self-diagnostic capabilities that alert operators to potential issues before they become major problems, thereby reducing downtime.

In terms of construction, Henny Penny's OFE/OFG series is built with durable stainless steel, making them resistant to rust and easy to clean. They also come with an efficient filtration system that prolongs oil life, ensuring that food quality remains high while minimizing costs associated with oil replacement.

Moreover, the OEA/OGA models are designed with energy efficiency in mind. Equipped with advanced heating technology, these fryers conserve energy without compromising performance, making them an environmentally friendly choice.

With precise temperature controls, robust safety mechanisms, and a focus on efficiency, the Henny Penny OFE/OFG-341, OEA/OGA-342, OFE/OFG-342, and OEA/OGA-341 models set a high standard in commercial frying equipment, catering to the needs of modern kitchens while delivering delicious, consistent results.